Specifications

39
ATTO Technology Inc. iPBridge Installation and Operation Manual
7.1.3 Diagnostic commands
ATTO iPBridge
diagnostic commands help validate iPBridge operation and diagnose/isolate iPBridge
faults. Event logging is a mechanism for on-site observation of internal iPBridge behavior such as
tracing commands received over the GbE from the host and return of data and status to the host.
BridgeModel
Reports model information about a specific iPBridge
get BridgeModel
BridgeName
Specifies name used to identify individual iPBridge units.
May be up to a maximum of eight characters. It is not the
World Wide Name (WWN).
set BridgeName [value]
Requires a SaveConfiguration command
get BridgeName
ClearEventLog
Clears the contents of the event log. No events are
recorded until the command has been completed.
ClearEventLog
ClearTraceLog
Clears the contents of the trace log. No events are
recorded until the command has been completed.
ClearTraceLog
DisplayEventLog
Displays the most recent page of event log entries. Typing
a +, - or = causes the next, previous or same page of event
log entries to be displayed. No events are recorded until
the command has been completed. Type <escape> to
disable the command, begin new log entries, and return
to CLI.
DisplayEventLog < + | - | =| ESC>
DisplayEventLogFilter
Filters the display of data using the
DumpEventLog
command for specific iPBridge subsystems when in
DisplayEventLog
mode. If enabled for a particular
subsystem and level, that subsystem and level are masked
when the command
DisplayEventLog
is issued.
Subsystem entries: Log level entries:
FC INFO
ENET WARN
NVRAM CRIT
PERF FAIL
ECC ALL
ALL
GEN
HTTP
iSCSI
Default: disabled
set DisplayEventLogFilter [subsystem] [level]
get DisplayEventLogFilter [subsystem] [level]
DisplayTraceLog
Displays the most recent page of trace log entries. Typing
a +, - or = causes the next, previous or same page of trace
log entries to be displayed. No events are recorded until
the command has been completed. Type <escape> to
disable the command, begin new log entries, and return
to CLI.
DisplayTraceLog < + | - | = | ESC>
DisplayTraceLogFilter
Filters the display of data using the
DumpTraceLog
command for specific ports when in
DisplayTraceLog
mode. If
all
is set for a particular port, all information
about that port are captured when the command
DisplayTraceLog
is issued. If
disabled
is set for a port,
no trace log entries for the port are displayed.
Default: all all all
set DisplayTraceLogFilter [scsi| all] [sb | all] [chkcond | all]
get DisplayTraceLogFilter [scsi | all] [sb | all]