Specifications

27
ATTO Technology Inc. iPBridge Installation and Operation Manual
6.1 ATTO ExpressNAV pages
Each page in the ATTO ExpressNAV interface provides information and/or configuration parameters
based on a specific topic. Each page can be reached through the menu at the side of each page An image
on each page’s header shows each port in the product faceplate. Each port is clickable and also takes
you to the appropriate page.
Status
Displays iPBridge information:
Vendor ID, product ID, firmware revision number
and serial number
Valid temperature range, current temperature
and current voltage
Ethernet port IP addresses and status
Serial Port configuration
Configures the baud rate and echo parameters. Refer to
Serial port configuration commands
on page 45 for
details on each option.
Time & Date configuration
Configures the real-time clock or accesses a remote
time server. Configurable options are:
Enable/disable Simple Network Time Protocol
Time Server and time zone
Manually set time and manually set date
Refer to
Maintenance commands
on page 43 for
details each parameter.
Ethernet port configuration
Configures each port independently for the following
parameters:
• Enable/disable DHCP
IP address, gateway, subnet mask and Ethernet
speed
• MTU
Refer to
Discover the IP address
on page 5 and
Ethernet commands
on page 47 for details.
Remote Management
Sends information about the operation of the
iPBridge to an E-Mail address using an intranet or
the Internet, or to an IP address using SMNP. You
may designate the person receiving notification of
conditions and the level of severity which prompt
notification.
Refer to
Remote system monitoring
on page 15.
SCSI configuration
Configures each port independently for the following
parameters:
• Bus speed
Enable/disable sync transfer
Enable/disable wide transfer
• Initiator ID
Enabled/disable bus reset on startup
• Enable/disable bus termination
Attached devices are listed for each bus and you can
reset each port from this screen.
Refer to
SCSI configuration commands
on page 49.
iSCSI configuration
Defines the iSCSI CHAP target name, account name
and secret and configures the following parameters:
• iSCSI Alias
• iSCSI Port Number
• Enable/disable iSNSLoginControl
• Enable/disable SpeedWrite
• Enable/disable CHAP settings: direction (in or
out)
Refer to
iSCSI commands
on page 51 for details on
each parameter.
Auto, Manual Target Management
Maps storage devices using the designations for
the iSCSI LUN. The easiest way to map devices is
to use the Automatic Target Management feature.
To map devices, you must connect the devices to
one of the iPBridge SCSI ports. To access mapped
devices over Ethernet, you must have a host
computer connected to one of the iPBridge
Ethernet data ports.
Refer to
Target management
on page 7.
Bridge configuration
Defines a name for the bridge, sets an admin user name
and password, a read only user name and password,
restores defaults or configures the following
parameters:
Minimum and maximum operating temperature
• Operating temperature warning