Instruction manual

28
ExpressNAV pages
All screens and parameters are not available for
all FibreBridge models. Use the following as a
guide only.
Command Line Interface commands are the basis
for the ExpressNAV pages. Refer to Command
explanations on page vi of the Appendix for
individual command information.
Status
Displays FibreBridge information
• Vendor ID
• Product ID
Firmware revision number
• Serial number
• Valid temperature range
• Current temperature
Ethernet port IP addresses
• Ethernet port status
World Wide identifiers: node name, port name
Fibre Channel port status
• SCSI port status
Ethernet port configuration
Configures each port independently for the
following parameters: use of DHCP, IP address,
IP gateway, IP subnet mask and Ethernet speed.
SNMP
Controls the use of SNMP protocol and displays
the trap recipient IP addresses.
For more information on SNMP, refer to Remote
monitoring, management on page 21.
Remote management
Controls the use of the SNMP protocol and the
ability to E-mail information. For more
information, refer to Remote monitoring,
management on page 21
Serial port configuration
Configurable options are baud rate and echo.
SCSI configuration
Each SCSI port is configured separately. Displays
include a list of attached devices for each bus.
Click on the individual bus for information on
each SCSI device such as device type, vendor ID,
Product ID and SCSI bus, target and LUN.
Fibre Channel configuration
Configurable options included whether to use
hard or soft addressing, how busy status is
reported, the data rate, connection mode and hard
address value. The node names and port names
are displayed.
Storage management
A list of attached SCSI devices and a list of
attached Fibre Channel devices are displayed.
Click on the individual bus or port for detailed
information on each device.
You may also reset SCSI ports on this page or
configure the following options: boot scan, boot
Fibre delay, SpeedWrite default and virtual drive
response.
Time & date configuration
Configures the time zone, real-time clock or
access remote time server.
Mapping
You may map drives using the ExpressNAV
Mapping page. Refer to Mapping devices on page
17.
Bridge configuration
Configurable options are passwords, user names,
minimum and maximum operating temperature,
operating temperature warning and identify
Bridge. You may also restore defaults.
Firmware
You may update firmware using the ExpressNAV
interface. Refer to Updating firmware on page 25.