Instruction manual

22
SNMP-based monitoring
The Simple Network Management Protocol
(SNMP) facilitates the exchange of management
information between network devices.
An agent resides in the FibreBridge which takes
information from the FibreBridge and translates it
into a form compatible with SNMP. If certain
conditions arise, the agent sends asynchronous
notifications (traps) to a client.
1 If you have not already, open an ExpressNAV
session. For instructions, refer to
Open an
ExpressNAV session
on page 27.
2 On the left hand menu, click
Remote Mgt.
3The
Remote Management page appears.
Click on the
enabled radio button next to the
SNMP heading.
4 Click on the appropriate radio button for
SNMP
Traps, SNMP Extended Traps
and Auto Log
Sense
.
SNMP Traps and SNMP Extended Traps
are notifications for SNMP functions such as
device transition and device error
Auto Log Sense controls whether current
data from log pages in a SCSI target device
is available automatically.
5 Enter the IP addresses of the those who should
receive messages (SNMP trap recipients) in
the text boxes on the left, and the type of
messages you wish each recipient to receive in
the drop down boxes on the right.
6 Click
Submit
Exhibit 4.0-2 Events triggering SNMP notification for extended or standard trap generation, severity level and
explanation
Event
Severity
Level
Extended
Traps disabled
Extended
Traps enabled
Explanation
Aborted
Command
Warning No Yes A command has been aborted
Device
Transition
Info No Yes A target device has failed, become offline or come
online
Fibre Channel
Loop Down
Info Yes Yes A loop down event on a Fibre Channel port has
occurred
Fibre Channel
Loop Up
Info Yes Yes A loop up event on a Fibre Channel port has
occurred
Hardware Error Critical No Yes An unrecoverable target device failure
Illegal Request Info No Yes An illegal SCSI request has been attempted
Medium Error Warning No Yes A command terminated with an error condition
that may have been caused by a flaw in the target
device’s physical medium or its recorded data.
Temperature Info Yes Yes The unit’s internal temperature has increased or
decreased to within standard operating ranges
Temperature Critical Yes Yes Unit’s internal temperature has increased to at or
above the maximum operating temperature or
decreased to at or below the minimum operating
temperature
Temperature Warning Yes Yes Unit’s internal temperature has increased to at or
within the unit’s maximum operating temperature
less the unit’s temperature warning offset or
decreased to at or within the unit’s minimum
operating temperature plus the unit’s temperature
warning offset
Unit Attention Info No Yes A unit attention condition has occurred
Unit Power On Info Yes Yes The unit has been powered up