Instruction manual
21
ATTO Technology Inc. FibreBridge Installation and Operation Manual
4.0 Remote monitoring, management
The Ethernet port provides monitoring and management using the ExpressNAV interface.
Remote system monitoring may be set up through
Remote Management page of the ExpressNAV
interface (see Exhibit 4.0-1) using the Simple
Network Management Protocol (SNMP) or E-
mail.
Various types of problems may invoke a
notification:
• Device errors such as medium error, aborted
command and hard error
• Device transitions from online to offline
• Critical and warning temperature conditions
• Critical and warning voltage conditions
• Power cycle/power failure conditions
Messages may state that a device is not working,
a medium has an error, or a command has been
stopped.
You may designate which warning level a
recipient receives. For example, a recipient with a
critical severity level only receives critical
messages and not warning or informational
messages.
In both monitoring systems, you select the
warning levels for each recipient:
• All: all warnings, critical events and
informational messages
•
Informational: informational messages
•
Warning: events which are either warnings or
critical events
•
Critical: only events which are critical
•
None: no messages are sent
Exhibit 4.0-1 The Remote Management page in the ExpressNAV interface