Setup guide

To scan your storage hardware:
1 Unload the Stone and Wire driver. Type:
/etc/init.d/stone+wire unload
2 Unload and reload the fibre channel drivers. Type one of the following
sequence of commands, according to your fiber channel card model.
If you have a QLogic
-based card, type:
rmmod qla2300
rmmod qla2400
rmmod qla2xxx
rmmod qla2xxx_conf
modprobe qla2xxx
modprobe qla2300
modprobe qla2400
If you have an ATTO-based card, type one of the following sequences
of commands:
For HP Z800 workstations, type:
rmmod celerity8fc
modprobe celerity8fc
For older HP workstations, type:
rmmod celerityfc
modprobe celerityfc
NOTE Depending on the storage you are running, your system might not
use all of the drivers listed. If your system does not use a driver listed, the
commands to unload or reload the drivers will fail. You can ignore these
failures. They just indicate that the driver is not required by your system.
3 Reload the Stone and Wire driver. Type:
/etc/init.d/stone+wire reload
Your filesystem should now be mounted.
Verifying Disk Usage
You cannot write to storage partitions that are completely full.
If you receive error messages stating that the framestore is full, use the sw_df
command to check disk usage.
222 | Chapter 6 Advanced Configuration and Troubleshooting