Setup guide
2 Depending on the result of the previous command, do one of the
following:
■ For clips with frames listed as missing, contact your local Autodesk
support representative for help on resolving this issue.
■ For clips with frames listed as remote, perform the following
procedure.
To recover remote frames:
1 Archive all clip libraries that are reported as containing remote frames.
In the previous example, the fourth library (from_caplan) contains remote
frames.
2 Rename the libraries you just archived, such as by adding the remote
suffix to the library name.
3 Restore the clip libraries from the archive. All the frames referenced by
the clips should now be stored locally.
4 Delete the original libraries.
Verifying that the Disks are Available to the Operating
System
If your disks or logical drives are not visible in the output of the sw_df
command, verify that they are visible to the operating system.
To verify that the disk/controller is available to the operating system:
1 Run the command that will provide you with a list of all the controllers
or disks on your system.
cat /proc/scsi/scsi
A listing of all controllers and hard disks attached to your system appears.
2 If any controllers or hard disks in your configuration are not visible,
check the connections and cabling to your storage device, and ensure
that your storage hardware is running.
If you must reconnect or tighten connections to your storage hardware, it is
a good idea to rescan your hardware to ensure that the operating system is
able to communicate with it.
Visual Effects and Finishing Troubleshooting | 221