- ATTO FibreBridge Operation Manual

22
Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format.
Subject: [The Type of Event that Occurred]
Message Body:
This is a status message from [FibreBridge name]. Identifying information as
well as the most recent entries from the event log appear below.
*************** Unit Information ***************
Serial Number : [Serial Number]
IP Addresses: [IP Address1]
[IP Address2]
*************** Event Log Entries ****************
[Listing of the ten latest event log entries]
Exhibit 3.0-6 Events triggering an Email message, severity level and explanation
Event
Severity
Level
Explanation
Aborted Command Warning A SCSI command discovers a command has been aborted.
Device Down Warning A target device has failed or become offline.
Hardware Error Critical A SCSI command discovers an unrecoverable target device failure.
Medium Error Warning A command terminated with an error condition that may have been caused by a
flaw in the target device’s physical medium or its recorded data.
Temperature Critical Unit’s internal temperature has increased to at or above the maximum operating
temperature or decreased to at or below the minimum operating temperature.
Temperature Warning Unit’s internal temperature has increased to at or within the unit’s maximum
operating temperature less the unit’s temperature warning offset or decreased to
at or within the unit’s minimum operating temperature plus the unit’s temperature
warning offset.
Unit Power On Info The unit has been powered up.
Voltage Critical A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level
......
VDDA (3.30V)
.......
VDDB (2.50V)
......
VDDC (1.50V)
.....
VDDD(1.35V)
Low
........ .......
5%
....................
4%
.......................
5%
..................
4.5%
High
...............
8%
....................
5%
......................
5%
.................
5%
Voltage Warning A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level
......
VDDA (3.30V)
.......
VDDB (2.50V)
......
VDDC (1.50V)
.....
VDDD(1.35V)
Low
........ .......
3%
....................
3%
.......................
3%
..................
3%
High
...............
5%
...................
3.5%
....................
3%
.........., .....
3%