Buffer ID nvram offset Buffer Description (default values*)
9: Reserved
a: 0x27 Hard Address (default 0x03)
b: 0x28 Cache Options (default 0x00)
Bits 7 -2 - Reserved
Bit 0 - Disk Caching 1 = Disk Caching Only 0 = No Caching
c: 0x29 SCSI Adapter 1 Options (default 0x0F)
d: 0x2A SCSI Adapter 2 Options (default 0x0F)
Bits 7-5 - Reserved
Bit 4 - Power On Bus Reset 1 = Suppressed 0 = Not Suppressed
Bit 3 - Tagged Command Queuing 1 = On 0 = Off
Bit 2 - Wide Narrow Transfers 1 = Wide 0 = Narrow
Bit 1 - Sync/Async Transfers 1 = Sync 0 = Asynch
Bit 0 - Ultra/Fast Wide Transfers 1 = Ultra 0 = Fast Wide
e: Reserved
f: Reserved
10: 0x2B - 0x2D Physical Device Addressing Method (default 0x82 0x04 0x44)
Consists of 3 hex bytes bb ll tt (bb=busid, ll=lun, tt=target id).
The left hex digit is the bit number of the rightmost field bit in the LUN.
The right hex digit is the number of bits in the field.
11: 0x31 - 0x33 Logical Unit Addressing Method (default 0x52 0x05 0x84)
See Physical Device Addressing Method.
12: 0x2E - 0x30 Virtual Device Addressing Method (default 0x02 0x63 0x24)
See Physical Device Addressing Method.
13-15: Reserved
16: 0x23 ATTO FibreBridge Options (default 0x00)
Bit 5-7: Reserved.
Bit 4: Translate QUEUE FULL to BUSY, 0 = Disable, 1 = Enable
Bit 2-3: Reserved.
Bit 1: Enable/Disable Bridge Soft Fibre LUN,1 = Enable, 0 = Disable (FBE)
(uses FibreBridge Soft Fibre LUN byte to determine actual ID)
Bit 0: perform/suppress LUN translations, 1 = perform, 0 = suppress.
17: Reserved
18: 0x37 - 3E ATTO FibreBridge Name (default space characters (0x20)
User defined printable ASCII string intended to facilitate user identification
of each FibreBridge. This string is returned by the INQUIRY command in the
ASCII implemented operation definition page (0x82) when the EVPD bit is set
to 1.
19: 0x25 SCSI Adapter 1 Selection Timeout (default 0x0b)
1a: 0x26 SCSI Adapter 2 Selection Timeout (default 0x0b)
Buffer Value Timeout Value Buffer Value Timeout Value
>=0x0b 256ms 0x06 8ms
0x0a 128ms 0x05 4ms
0x09 64ms 0x04 2ms
0x08 32ms 0x03 1ms
0x07 16ms <=0x02 256ms
1b: 0x01 ATTO FibreBridge Type
0x00 = FibreBridge 2100R
0x01 = FibreBridge 3100R