Product data

ATTO Technology, Inc. ATTO FibreBridge Software Manual
- -
41
ATTO Technology, Inc.
Device Element for Control Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Control
1 Reserved
2 X X X X X X
RQST
IDENT
X
3 X X RQST
FAULT
DEVICE
OFF
(RESET)
X X X X
Rqst Ident: Causes the device front panel to flash an identification signal.
Rqst Fault: Causes the device front panel to flash a fault signal.
Device Off: Causes the device to perform a software reset.
Temperature Sensor Element for Control Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Control
1
2
3
Reserved
Common Control-Disable: If Disabled, will not report Warning or Error conditions based on temperature.
SCSI port/transceiver Element for Control Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Control
1
2
Reserved
3 Reserved Disable Reserved
ATTO FibreBridge GBIC Connector Element for Control Page (3100R and 3200R only)
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Control
1
2
Reserved
3 Reserved Online Mode
Online Mode: 00 : Normal - FibreBridge determines Online/Offline status
01 : Force Online - Fibre Channel is always Online
02 : Force Offline - Fibre Channel is disabled until POR