Product data

ATTO Technology, Inc. ATTO FibreBridge Software Manual
- -
40
ATTO Technology, Inc.
Enclosure Control Page for ATTO FibreBridge 3100R and 3200R
Byte
0 1 2 3
0 02 Cond. Bits 00 0x48
4 Generation Code
8 Overall Control – Device
12 Element Control – Device
16 Overall Control – Power Supply
20 Element Control – Power Supply A
24 Element Control – Power supply B
28 Overall Control – Temperature Sensor
32 Element Control – Temperature Sensor
36 Overall Control – SCSI Ports
40 Element Control – SCSI Port 1
44 Element Control – SCSI Port 2
48 Overall Control – Language
52 Element Control – Language
56 Overall Control – GBIC Ports
60 Element Control – GBIC Port 1
64 Element Control – GBIC Port 2
68 Overall Control – POST Code
72 Element Control – POST Code
76 Overall Control – NVRAM Reset
80 Element Control – NVRAM Reset
Generation Code – must be 0.
Every Control Element starts with a Common Control byte. The common control byte is used to choose
which fields to update based on the page. If an element should be ignored by the ATTO FibreBridge, the
Select bit must be 0. Conversely, to tell the ATTO FibreBridge to implement the changes specified in the
Control Element, the Select Bit should be set to 1.
Common Control is defined as follows:
Bit
Byte
7 6 5 4 3 2 1 0
0 Select
Reservd DISABLE Reservd Reserved
SELECT – Set to 1, signals the ATTO FibreBridge that the Control Element should be used to change
ATTO FibreBridge Configruation. Set to 0, signals the ATTO FibreBridge to ignore the Control Element.
DISABLE – used in the Temperature Control Element to stop the ATTO FibreBridge from raising an
error based on over/undertemp status.
For Example, to Disable SCSI Port 1 only, and leave the rest of the configuration the same, All Overall
Control and Element Control Fields should have the Select bit CLEARED, except for the SCSI Port 1
Element, which should have the Select bit SET and the disable bit in byte 3 SET.