Element Definitions:
Device Element for Status Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Status
1 Slot Address
2 0 0 0 0 0 0
IDENT
1
3 0 Fault
Sensed
Fault
Reqstd
0 0 0 0 0
Slot Address: SCSI ID of this bridge (thumbwheel switch #1).
Ident: Set to indicate the Identification control bit has been set.
Fault Sensed : Set to indicate a fault detected by this bridge.
Fault Reqst: Set to indicate that the RQST FAULT control bit has been set.
Power Supply Element for Status Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Status
1 Reserved
2 Reserved 0 0
0
0
3 0 0 0 Off 0 0 0 DC Fail
Off: Set if this power supply is off.
DC Fail: Set if this power supply is not supplying DC Power.
Temperature Sensor Element for Status Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Status
1 Reserved
2 Temperature
3 Reserved OT
Failure
OT
Warning
UT
Failure
UT
Warning
Temperature: Degrees Celsius-20. (cannot be 0)
OT Failure/Warning: Overtemperature status. Warning occurs at +40C. Error occurs at +50C.
UT Failure/Warning: Under Temperature status. Warning Occurs at +5C. Error occurs at 0C.
SCSI port/transceiver Element for Status Page
Bit
Byte
7 6 5 4 3 2 1 0
0 Common Status
1 Reserved
2 Reserved 0
3 Reserved Disable
d
Reserved 0 Xmit fail
Disabled: Indicates that the port has been disabled.