Product data

ATTO Technology, Inc. ATTO FibreBridge Software Manual
- -
35
ATTO Technology, Inc.
Enclosure Status Page for ATTO FibreBridge 2200R/D, 3100R and 3200R
Byte
0 1 2 3
0 02 Status Bits 00 0x58
4 Generation Code (fixed at 00 00 00 00)
8 Overall Status – Device
12 Element Status – Device
16 Overall Status – Power Supply
20 Element Status – Power Supply A
24 Element Status – Power supply B
28 Overall Status – Temperature Sensor
32 Element Status – Temperature Sensor
36 Overall Status – SCSI Ports
40 Element Status – SCSI Port 1
44 Element Status – SCSI Port 2
48 Overall Status – Language
52 Element Status - Language
56 Overall Status – GBIC Ports
60 Element Status – GBIC Port 1
64 Element Status – GBIC Port 2
68 Overall Status – POST Code
72 Element Status – POST Code
76 Overall Control – NVRAM Reset
80 Element Control – NVRAM Reset
The Enclosure Status Page contains one entry for each status element reported by the ATTO Fibre
Bridge. See Element Definitions – Below.)
Short Status Page
Byte
0 1 2 3
0 08 Overall Status 00 00
The Short Status page Contains one Overall Status byte, which contains the same information as the
‘Common Status’ byte of the Overall Status – Device field from the Enclosure Status page.
Common Status
Bit
Byte
7 6 5 4 3 2 1 0
0 Reserved Status Code
Where Status Code is
00h Unsupported
01h OK
02h Critical Error
03h Noncritical Error
04h Unrecoverable Error
05h Not Installed
06h – 0Fh Reserved