Product data

ATTO Technology, Inc. ATTO FibreBridge Software Manual
- -
15
ATTO Technology, Inc.
ErrorLog for ATTO FibreBridge 3100R
Syntax: set ErrorLog clear
get ErrorLog
Returns: [ Error Logs Cleared |
The last error code saved was xx
A xxx type error was detected since last error log clearing
Specific error text ]
Where xxx is : [ 960 |Static Memory | Synchronous DRAM | ISP2100 |
Symbios 896 A | Symbios 896 B | FibreChannel | Software]
and Specific error text is one line of descriptive error text.
ErrorLog for ATTO FibreBridge 2200R/D and 3200R
Syntax: set ErrorLog clear
get ErrorLog
Returns: [ Error Logs Cleared |
The last error code saved was xx
A xxx type error was detected since last error log clearing
Specific error text ]
Where xxx is : [ 960 |Static Memory | Synchronous DRAM | ISP2200 |
Symbios 896 A | Symbios 896 B | FibreChannel | Software]
and Specific error text is one line of descriptive error text.
IdentifyFibreBridge
Syntax: set IdentifyFibreBridge [enabled | disabled]
get IdentifyFibreBridge
Returns:
(terse) [enabled | disabled]
(verbose) IdentifyFibreBridge = [enabled | disabled]
Enabling this option will cause the 'Ready' LED on the front panel of the FibreBridge to blink. The
LED will continue to blink until this parameter is disabled.
DispEvent
Syntax: set DispEvent [subsystem][event_level][status]
get DispEvent
Returns:
(terse) XX XX [all | ngood]
(verbose) DispEvent = SubSys:XX Lvl:XX Status:[all | ngood]
The DispEvent command sets the switches which control the filtering performed when displaying
events. The switches have the following meanings and possible settings:
[subsystem] switch is a mask that controls which subsystem’s events are displayed.
The mask is a byte value with the following bit patterns corresponding to the currently
supported subsystems:
01 FCP Processor/i960
Interaction
02 SCSI Processor/i960
Interaction
04 Ethernet
10 GBIC Connector
20 NVRAM & Flash
To display the events from several different subsystems, use a mask value equal to