Specifications

25
24
APPENDIX 3
and the Premier Base it will download.
To determine if a radio link is currently possible the Premier Base can
be put into monitor mode. This is done by running the PBase Activity
Monitor Utility program which can be found at "C:\Program
Files\Strt\Inboundwire\PbasMon.exe".
While in monitor mode note the Radio ID numbers on screen in the
PBase Activity Monitor program window, if the Radio ID is followed by
"wireless error" then the Premier Base is not currently able to connect
wirelessly with the mobile unit. Try moving the mobile unit closer to
the Premier Base. If the Radio ID number does not appear in the
PBase Activity Monitor program screen then the Premier Base may
not configured to search for the correct number of mobile units.
The Premier Base can search for up to thirty Radio ID's beyond it's
own. For example if the Premier Base Radio ID is 9000001 it will
search for the next sequential Radio ID of 9000002 and so on, up to
9000031. To save download time the Premier Base can be
configured to search for a limited number of Radio ID's.
To adjust the number of Radio ID's the Premier Base will search for:
From the Administrator click Shadow Tracker, click Maintenance and
then click Base Unit Configuration, the current setting will be displayed
there. This setting should match the number of mobile units that you
have.
If you change this setting it will only be updated in the Premier Base
after the PbasWcfg.exe program is run. The PbasWcfg program is used
to configure the Premier Base. This program is executed
automatically whenever you make changes to the Base Unit
Configuration and click the Set Base Configuration button. The
PbasWcfg program can also be found in the "InboundWire" folder.
Data flow through the system
APPENDIX 3
The Premier Base wirelessly downloads and stores the historical data
from the mobile units independently, without the need for a computer.
The historical data remains in non-volatile memory in the Premier
Base until a download is requested by the Shadow Tracker
Professional software program.
When a download is either requested or scheduled from the Premier
Base the WirelessGrabber executes the PBase Data Extractor program,
which handles the communications and data transfer between the
Computer and the Premier Base. (above)
The PBase Data Extractor program downloads the data from the
Premier Base and writes a binary file for each unit, with a .BIN
extension, into the InboundWire folder then the Premier Base is