Datasheet

SERIES:
207A-ABA0-R
FILE:
207A-ABA0-R_spec
SPECIFICATION AND PERFORMANCE
DATE:
2013/01/16
ELECTRICAL
Item Requirement Test Condition
Contacts Resistance Initial: 30m max
Final: 100m max
EIA 364 –23
Subject mated contacts assembled in
housing to 20mV maximum open circuit at
100mA maximum.
Insulation Resistance 100 M minimum EIA 364 – 21
Test voltage 100±10V DC between
adjacent contacts of mated and unmated
connector assemblies. Interval of shield
case and contacts too, in the same way.
Dielectric
Withstanding Voltage
No flashover & spark
over & excess leakage
& breakdown.
EIA 364 – 20
Test voltage 100V AC between adjacent
contacts of mated and unmated connector
assemblies for one minute. Interval of
shield case and contacts too, in the same
way.
Temperature Rise 0.5A at 250V AC
minimum when
measured at an
ambient temperature
of 25. With power
applied to the
contacts, the
T must
not exceed +30 at
any point in the
connector under test.
EIA 364-70, method B
The object of this test procedure is to
detail a standard method to assess the
current carrying capacity of mated
connector contacts.
Contact Capacitance 2pF maximum
unmated per contact.
EIA 364 – 30
Test between adjacent circuits of unmated
connectors at 1KHz.