Technical information

MODIFICATIONS OF BOILERS ATTACK DP, DPX
ATTACK DP StandarD, ATTACK DPX StandarD
Wood gasifying boiler "ATTACK DP, DPX Standard" is controlled by boiler and flue gas thermostat.
Wood gasifying boiler "ATTACK DPX " is euipped with three types of regulation: STANDARD, PROFI, LAMBDA
1 - Emergency thermostat with reset
2 - Fuse
3 - Main switch
4 - Flue gas thermostat
5 - Boiler thermostat
6 - Thermomanometer
Description:
1. Reset - boiler protection against overheating (after achieving temperature higher than 110°C is boiler
disconnected from electricity mains)
2. Fuse - boiler protection against short circuit
3. Main switch - boiler start and in the case of need also complete boiler stop
4. Flue gas thermostat - when the flue gas temeprature decreases under the set value,the fan is stopped
5. Boiler thermostat - serves for setting of required temperature of water in boiler (when the set temperature
is exceeded,
the fan is stopped and boiler works at min. output;when the temperature decreases, the fan is started again
and boiler works at max. output)
6. Thermomanometer - shows output temperature and actual pressure of heating water in boiler
ATTACK DP PROFI, ATTACK DPX PROFI
Wood gasifying boiler "ATTACK DP, DPX Profi" is controlled by electronic regulator, which is intended to regulate temperature of
warm water boilers for wood combustion. Advantage of the Profi version of ATTACK boilers in comparison with the Standard
version is represented by higher attendance comfort, possibility of boiler output regulation to achieve optimal parameters by
wood combustion. Regulator permanently measures temperature of water in the boiler and indicates its value on display and
also controls flue gas thermostat and C.H. pump.
Wood gasifying boiler "ATTACK DP " is equipped with two types of regulation: STANDARD, PROFI
2 3 51 4 6
1 2 3 4 5 6
9 8 7
10
11
ATTACK DP 75-95
ATTACK DP, DPX 25-45
2 3 51 4 6
ATTACK DP 75-95
ATTACK DP, DPX 25-45