Specifications

18 |
ATTACK AS
ATTACK
OVENTROP
ATTACK SLX, DPX, DP
1 950 mm
1 500 mm
2 000 mm
INSTALLATION OF
FLUE CONNECTION
Flue connection can be installed
horizontally or vertically on the
boilers DPX and SLX. This is possi-
ble by turning the flange by 180°.
FUEL
Chopped dry wood logs with humidity of 12–20 % are the prescribed fuel. It is also pos-
sible to use big pieces of the wooden waste together with thick wood logs.
The boiler is not intended for combustion of the saw dust and small wooden waste.
The small wooden waste can be burned together with the wood logs (max. 10 % share).
Boiler output depends also on the humidity of the wood. The correct output and the
proper function of the boiler are guaranteed by the humidity up to 20 %.
The ATTACK WOOD & PELLET stainless steel burner is intended for combustion of the wood
pellets following the norm DIN with max. humidity of 12 %, diameter of 610 mm, length up to 35
mm and recommended ash content of 1 %. There is possibility to burn alternative fuel types like
olive pits and pit crumb. All the prescribed fuels should achieve the heat value of 15–17,5 MJ/kg.
BOILER PROTECTION AGAINST OVERHEATING
Each model of the ATTACK SLX, DPX, DP is equipped with an exchanger
against overheating. After connection of the STS 20 valve with the probe placed
in the rear part of the boiler, it protects the boiler against overheating. When
the temperature of water in the boiler exceeds 95 °C, it lets the water flow into
the cooling circuit to absorb the surplus heat and to discharge it into the drain.
EXAMPLE
OF INSTALLATION
The required dimension of the boiler room
with the ATTACK SLX, DPX, DP boiler connected
to the accumulation tank ATTACK AS and the solar collectors.
ATTACK SLX, DPX, DP
MODEL LINE 7000, 6000, 5000