Specifications

12 |
DESCRIPTION
1. Reset – boiler protection against overheating (after exceeding the tem-
perature of 110 °C is the boiler disconnected from electricity mains)
2. Fuse – protection against short circuit
3. Main switch – boiler start and boiler stop for the case of need
4. Flue gas thermostat when the temperature of the flue gas decreases
under the adjusted value, the fan is switched off
5. Boiler thermostat – serves to set the required temperature of the water
in boiler (in case of exceeding is the fan switched off and the boiler
works at min. output, after decreasing of the required temperature is
the fan switched on again and the boiler works at maximum output)
6. Thermo-manometer – shows the output temperature and the actual
pressure of the heating water in boiler
ATTACK SLX, DPX, DP
STANDARD
The wood gasifying boiler ATTACK SLX, DPX, DP Standard is
controlled by the flue gas thermostat and the boiler thermostat.
ATTACK SLX, DPX, DP  STANDARD
MAIN ADVANTAGES
OF THE BOILER LINE
ATTACK SLX, DPX
The boiler line ATTACK 7000 SLX and ATTACK 6000
DPX is equipped with the most efficient tubular heat
exchanger „flue gas-water. Special movable turbulators
installed inside the exchanger serve to brake and to make the
turbulent flow of the flue gas through the heat exchanger.
Thereby it comes to higher heat transfer through the steel
exchanger wall into the heating water. Turbulators also ena-
ble the exchanger cleaning. The clean exchanger reaches the
most effective operation parameters – the high efficiency.
From technical view it is a boiler line with high efficiency,
low flue gas temperature and more effective combustion
process. Achieved efficiency of the ATTACK SLX boiler ex-
ceeds 91%. The efficiency of the boiler ATTACK DPX ex-
ceeds 90 %. By installation of more efficient boiler of the
ATTACK SLX line it comes to significant decrease of the
operating costs, projected into the fuel savings, in compari-
son with less efficient boilers that combust same fuel.
From the social-wide view, it is an environment-friendly
source, combusting wooden biomass, which is a kind of
CO
2
– neutral fuel.
Considering the creation of harmful emissions, the av-
erage concentration of CO value in the flue gas, is during
operation of the LAMBDA Touch version under the level of
200 mg/m
3
related to 10 % of O
2
.
Under the valid European norm EN303-5, classifying the
solid fuel boilers by efficiency and emissions to individu-
al classes, the ATTACK SLX, DPX boiler (version LAMBDA
Touch) reaches 5 times lower concentration of harmful
CO emissions in the flue gas in comparison with the al-
lowed level of this norm!
BOILER MODIFICATIONS
ATTACK DP, DPX AND SLX
The wood gasifying boilers ATTACK ® are equipped with the fol-
lowing types of regulation: STANDARD, PROFI and LAMBDA Touch.
ATTACK SLX, DPX, DP
MODEL LINE 7000, 6000, 5000