Instruction manual
9
ATTACK DPX PROFI
The ATTACK DPX Profi version in comparison with Standard version represents higher attendance
comfort, possibility of output modulation and possibility of connection of control and regulation
elements.
The boiler temperature is kept at the level set by the user, by setting up number of rotations of the
flue gas fan. The ATTACK PROFI boiler regulator measures the temperature of water in the boiler
continuously and indicates its value on the display, controlling pump of central heating at the same
time. There is a possibility to connect a room thermostat to boiler regulator. The room thermostat
ensures regulation of temperature of heated rooms. Control of gear of the four-way mixing valve is
possible as well.
1 – Electronic regulator
Profi
2 - Manometer
Frontal view of electronic regulator
1 - Switch of connection
2 - Display indicating boiler temperature
3 - Control light of heating up process
4 - Control light of boiler overheating
5 - Control light of room thermostat
6 - Knob of the boiler thermostat
7 - Control light of the C.H. pump operation
8 - Control light for insufficiency of fuel
9 - Knob of room thermostat
10 -TEST button (after pressing it,
the temperature set by knob 6 appears and the flue
gas fan is switched off for the moment )
Backward view of electronic regulator:
Setting of flue gas
fan speed during
burning up mode
Setting of post purge time of fan after reaching set up temperature of heating water
Fuse
2A
Connection of
mixing valve
(12 V)
Connecting of room temperature sensor or thermostat