Instruction manual
45
Oxygene probe (Lambda sonda)
4-conductor silicone-covered flexicord
with conductor´s crossection of 0,75mm2
white = warming 12V
black= + signal of probe
grey = - signal of probe
~
Probe
Probe
Probe warming
Probe
Probe 1: Probe -
Probe 2: Probe +
Probe 3: Probe warming
Probe 4: Probe warming
Temperature sensor
Terminal 1: Flue gas sensor F1 Pt100 Mount the flue gas sensor into the flue gas connection by the
bayonet flange!
Terminal 2: Flue gas sensor F1 Pt100
Terminal 3: Boiler sensor F2 Pt100 Do not extend connection conductor´s of sensors!!!
Terminal 4: Boiler sensor F2 Pt100
Terminal 5:
Terminal 6:
Values of resistance:
Boiler sensor and sensor of safety thermostat have to be
treated with warmwater paste, put into gasket and tighten by
holding spring!
Polarity is irrelevant
Air flapV1 – V2, circuiting pump, suction fan
For connection of circuiting pump and
suction fan, use 3-conductor flexicord
with conductor´s cross section of
0,75mm2!
C: SHADING CONDENSATOR
Terminal 3: Connection
Terminal 4: Connection 24V~
Terminal 5: Regulation signal secondary
Terminal 6:
┴
Y+(0/2-10V)
Regulation signal primary Y+(0/2-10V)
Terminal 12: L: Circuiting pump
Terminal 13: N: Circuiting pump
Terminal 14: PE: Circuiting pump
Terminal 15: L: Suction fan
Terminal 16: N: Suction fan
Terminal 17: L: Free
Terminal 18: PE: Suction fan