Instruction manual

22
Cancelling of the manufacturer´s function
This process requires code of manufacturer. It is possible to set operation hours of the boiler, to
reset number of overheatings, as well as last 10 combustions can be set to zero value.
Enter and exit to appropriate submenu is similar as in the Chapter 8.1. If no button is pressed
within 1 minute, regulator automatically switches to operation display.
Selection Submenu Indication
Information
Test of device
Safety test
Code
---
Set the code by +“ button. Chnage the random
number that appears on the right to the
manufacturer´s code and confirm by “. Next
setting appears.
Cancel
YES/NO
Choose YES by „+“
Next explanation appears after pressing„ and
menu expires.
By pressing YES solution to set boiler operation
hours and complete excess temperature, while last 10
combustions are set to 0
Setting
33 : Output decrease
YES/NO
Choose YES by „+“
Next explanation appears after pressing„and menu
expires.
By pressing YES solution, boiler output decreases to
20% in case that boiler temperature excesses
adjusted value for 2K
Finish
Testing
Test of device and safety test has to be done in the presence of the heating technician!
Test of device
Test of device is possible, only if the boiler is shut down!
Test is possible, only if there is no danger of overheating!
Test is selected and done by the menu button „“ (enter into Selection menu). Next menu selection
is displayed by the „test of device“ button and confirmed by „“ button. Then, the appropriate step
of the test is activated by the „+“ or deactivated by the „-“. Every next step is selected by „“. Test
of device is finished with the last point of the test by the „“ button and display is automatically
switched to operation mode. Test can be aborted also by early pressing of the „+“ and „-“ buttons at
once.
In case that no button is pressed within 15 minutes, display is automatically switched to operation
mode.