Specifications

Z8/Z8m Elliptical Owner’s Guide
More Data Readouts
TEST MODE
114
TEST MODE
Ext SRAM: Confirms static RAM system is operating. Example
value: PASS.
PWM Drive: Actual pulse width modulation value. When
cursor is under PWM target, should be close to or match PWM
Target. Example value: 12157.
Load Target: Not used.
Load Sense: Current in amperes from the electromagnetic
brake load coil. Example value: 0.85.
Load ON/OFF: Enables or disables LCB load feedback control.
Should always be ON. If OFF, the LCB will ignore the PWM
drive signal and remove the load current feedback. Example
value: ON.
Keypress: Pressing each key will play a tone and identify the
key on the display.
S-Caps: Voltage level of super capacitors, which provide power
for the elliptical during workout pause. About 45 seconds of
pedaling should result in a full charge of 4.82 volts. Example
value: 4.82.
Watts: Actual watts as measured from the electromagnetic
brake. Example value: 125.