Atrie WireSpan 3000/3000E MODEM User's Manual
WireSpan 3000/3000E USER'S MANUAL
ATRIE WireSpan 3000/3000E USER'S MANUAL (Version 3) ATRIE TECHNOLOGY INC. 10 Floor,14 , Lane 609, Sec.5, Chung Hsin Rd., San Chung City, Taipei Hsien, Taiwan 241, R.O.C. TEL:+886-2-29995155 FAX:+886-2-29994960 Web:www.atrie.com.tw Mail:contact@mail.atrie.com.tw th (C) Copyright 2001 ATRIE TECHNOLOGY INC.
TABLE OF CONTENT CHAPTER 1 INTRODUCTION Overview.................................................1-1 Applications...................................................1-3 CHAPTER 2 INSTALLATION Package Contain......................................2-1 Panel Description...................................2-1 Cabling Your WireSpan 3000 ..........................2-5 CHAPTER 3 GETTING START The Front Panel LCD Controller........................3-1 Menu Tree Operation......................................
CHAPTER 1 INTRODUCTION Overview The WireSpan 3000/3000E is a HDSL (High-bit-rate Digital Subscriber Line) digital modem. It provides full duplex (bi-directional) 1.544Mb/s (T1) or 2.048Mb/s (E1) transmission capability over two non-loaded two-wire metallic cable pairs. Specifically, bi-directional data at a rate of 784kb/s or 1168kb/s is transmitted and received on each pair. Figure 1-1, 1-2 illustrated a generic dual duplex HDSL system.
HTU-C HTU-R Loop1 1.544Mbps or 2.048Mbps T1/E1 Interface Circuit N x 64K Transceiver Loop2 T1/E1 Interface Circuit Transceiver N x 64K T1/E1 Interface 1.544Mbps or 2.048Mbps T1/E1 Interface RS-530/V.35 RS-449/X.21 RS-530/V.35 RS-449/X.21 DTE DTE Figure 1-1 WireSpan 3000 HTU-C HTU-R Loop1 1.544Mbps or 2.048Mbps T1/E1 Interface Circuit Transceiver Transceiver Loop2 T1/E1 Interface T1/E1 Interface Circuit 1.544Mbps or 2.
specification of the WireSpan 3000.
CHAPTER 2 INSTALLATION This chapter describes how to install and connect your WireSpan 3000/3000E. Step-by-step instructions guide you through installing your WireSpan 3000/3000E. Package Contain Carefully unpacking your WireSpan 3000. The package should contain the following items: 1. The WireSpan 3000. 2. One power cable. 3. One user's manual 4. One DTE Interface cable For WireSpan 3000E. The package should contain the following items: 1. The WireSpan 3000E. 2. One power cable. 3.
z z z Save and load the configuration profile View status information Execute the diagnostic HDSL NTU Figure 2-1 Front Panel E HDSL Termination Unit Figure 2-2 Front Panel 1. LED Indicators There are eight LEDs on the front panel of the WireSpan 3000/3000E . These LEDs display the real-time status of the WireSpan 3000/3000E. Table 2-1 lists the LEDs and describes their function.
AIS Alarm Indication Signal YEL Yellow Alarm framing Lights to indicate the presence of an alarm indication signal on the E1 receive signal Lights to indicate the presence of a yellow alarm on the E1 receive signal 2. Control Keys The front panelís four control keys allow you to access the configuration menus, options, and settings that appear in the front panel display. Table 2-2 lists and describes the function of each control key.
OFF T1/E1 RX CON ON T1/E1 TX T1/E1 HDSL AC Figure 2-4 rear panel WireSpan 3000E (AC POWER) Figure 2-5 shows the rear panel of the WireSpan 3000.
Note: 1: TIP2 for HDSL loop2 2: RING2 for HDSL loop2 4: TIP1 for HDSL loop1 5: RING1 for HDSL loop1 Figure 2-5 RJ-45 for HDSL Line Interface Note: 1: Receive TIP1 for E1 loop 2: Receive RING1 for E1 loop 4: Transmit TIP2 for E1 loop 5: Transmit RING2 for E1 loop 7: Ground 8: Ground Figure 2-6 RJ-48 C for E1 Line Interface Cabling Your WireSpan 3000 This section describes how to connect your WireSpan 3000 to: (1) A personal computer (PC) or data terminal equipment (2) HDSL Line (3) E1 equipment (4) DTE In
SL HD /E T1 /E T1 1 1 TX /E1 T1 RX E DT M CO To Other HDSL ON AC F OF To DTE To E1 interface To Console To AC Power 90 ~ 260 V Figure 2-9 Connecting WireSpan 3000 (AC POWER) SL HD /E1 T1 /E1 T1 TX /E T1 1 RX E DT FG DC To Other HDSL 8V - 4 ON F OF To DTE To E1 interface To Console To DC Power -36 ~ -72 V Figure 2-10 Connecting WireSpan 3000 (DC POWER) 2-6
Cabling Your WireSpan 3000E This section describes how to connect your WireSpan 3000E to: (1) Personal computer (PC) or data terminal equipment (2) HDSL Line (3) E1 equipment Instructions for installing each cable shown in Figure2-6 SL HD /E1 T1 /E1 T1 TX /E1 T1 RX M CO To Other HDSL ON AC F OF To E1 interface To Console To AC Power 90 ~ 260 V Figure 2-11 Connecting WireSpan 3000E (AC POWER) 2-7
SL HD /E1 T1 /E1 T1 TX /E1 T1 RX FG DC 8V - 4 To Other HDSL ON F OF To E1 interface To Console To DC Power -36 ~ -72 V Figure 2-12 Connecting WireSpan 3000E (DC POWER) 2-8
CHAPTER 3 GETTING START There are two methods to control the WireSpan 3000/3000E ,one is using the front panel LCD controller; the other is using the console port on the rear panel. The Front Panel LCD Controller The front panel LCD controller consists of the LCD display and front panel switches. The menu tree consists of several categories. Each category has several options (STATUS, CONFIGURE, DIAGNOSTIC, etc.) Many of these options are configurable, while others indicate the device status.
120 OHM: To indicate E1 interface impendence such as 120 OHM or 75 OHM or DISABLE (when E1 interface unused ). HDB3: To indicate line coding method such as HDB3 or AMI when in non loop back mode .To indicate loop back mode such as LL or DL. There are four categories under main menu: Status, Configure, Diagnostic and Profile. The function of every categories are describe below: Status This category shows the Loop Status, E1 Status, Monitor and Rest.
CTS option, Interface type. E1 Setup : Aux : Ts Mapping : Sys Rst : Configures the E1 line parameters, such as: framing, cable length and terminal type. Setup the auxiliary parameters, including: clock source, keylock enable and keylock password. This option maps the appropriate time slots to the respective DTE port. Rests the whole WireSpan 3000/3000E. Diagnostic The diagnostic allows user to do variety of loop back to assist user in isolating network problem.
DIAGNOSTIC MENU [MAIN] C DIAGNOSTIC This menu provide self-test,helping user to find out the problem and fix it. PROFILE MENU [MAIN] C PROFILE This menu provides the user 5 user profile to save or load,also provide the factary setting. STATUS MENU [MAIN] C STATUS Press ENTER key to enter loop status Menu. < STATUS > LOOP STATUS This screen shows the HDSL Loop status,press ENTER to show Loop1, Loop2 STATUS. <> L1:ON L2:OFF ON: on Line OFF: off Line Press Right key shows the CERR STATUS.
<> CERR Press ENTER to display the Loop1,Loop2 CRC ERROR count. CERR: CRC ERROR COUNT L1:*** CERR L2:*** Press EXIT to return to CERR STATUS screen,Press Right key to enter FEBE STATUS screen. FAR END BLOCK ERROR COUNT DISPLAY SCREEN <> FEBE FEBE: Far-End Block Error L1:*** FEBE L2:*** This screen displays the HDSL Loop1 and Loop2 Far-End Block Error count . Press Exit key to return to FEBE STATUS screen, press Right key to show the Input Signal Level screen.
<> L1:***L2:***dB This screen shows the HDSL Loop1, Loop2 DC OFFSET level. Press Right key shows the FESA STATUS. FAR-END SIGNAL ATTENUATION DISPLAY << FESA >> L1:***L2:***dB FESA=Far-End Signal Attenuation This screen shows the HDSL Loop1, Loop2 FAR-END SIGNAL ATTENUATION. Press Right key to show the NOISE MARG screen. NOISE MARGIN DISPLAY <> L1:*** L2:***dB NOISE MARG=Norise Margin This screen shows the HDSL Loop1, Loop2 receiving Noise Margin.
DTE STATUS MENU DTE This screen displays WireSpan 3000's DTE interface signal status and timeslot status. Press ENTER to show the signal status. THE DTE CONTROL SIGNAL STATUS SCREEN 1:CTS_ DSR_ 1:RTS_ DTR_ This status screen shows the CTS,DSR,RTS,DTR status of the DTE interface. Press ENTER to show the timeslot status. THE DTE TIMESLOT STATUS DISPLAY SCREEN <> TIMESLOT STATUS Press ENTER to show the timeslot status.
E1 LOCAL RECEIVING RLOS* AIS_ LOF* YEL_ RLOS = Receive Loss Signal LOF = Loss Frame AIS = Alarm Indication Signal YEL = Yellow There will be * mark shown beside each alarm if present. LOCAL LINE STATUS BPV:_ TSHORT:_ BPV = Bipolar Violation TSHORT = Transmit Short There will be * mark shown beside each alarm if present.
LCV = Line Code Violation count FEBE = Far-End Block Error count PERFORMANCE MONITOR PERF MONITOR E1 OR HDSL PERFORMANCE MONITOR <> E1* HDSL The performance monitor shows the E1 and HDSL Receiving signal performance. Due to the size of the LCD display, the result will be shown on the CONSOLE port. Put the * mark on the E1 or HDSL and press the ENTER key to enter the performance screen.
15M ES-CRC: 15 MINUTES SEVERELY ERROR SECOND-CRC The second count of CRC error more than 30% in each second during last 15 minutes.Press ENTER key to show Loop1,Loop2 performance selecting screen. <<<<15M SES>>>> L1:* L2:* Select the desire Loop1 or Loop2. Press ENTER key to get the performance screen from console port. HDSL PERFORMANCE MONITOR (24 HOURS) <<>> 24H ES-CRC 24H ES-CRC: 24 HOURS ERROR SECOND-CRC Press ENTER key to select the Loop1 or Loop2 performance monitor.
Select the desire Loop1 or Loop2 to get the performance screen from CONSOLE port.
<> YES* NO Slect YES and press ENTER key will clear all the error counter. CONFIGURE MENU [ MAIN MENU ] CONFIGURE DTE CONFIGURE MENU (THIS MENU EFFECT ONLY IN WireSpan 3000 MODEL) DTE This Menu can activate, configure the DTE port. DTE PORT ACTIVATE <> DTE ACT STATE This screen can activate the DTE port. All the configuration must activate the DTE port to in effect. <<>> ON* OFF Slect ON to activate the DTE port, OFF to inactivate the DTE port.
<<>> NORM* INV* Select the Normal or Inverse output of clock signal. DATA OUTPUT POLARITY <> DATO POLARITY This screen selects the polarity of data output. <<>> NORM* INV* Select the Normal or Inverse output of data signal. DCD OPTION <> DCD OPTION Press ENTER key to select DCD option. <<>> ON* OFF Select the desire option (ON or OFF) for DCD signal. DSR OPTION <> DSR OPTION Press ENTER key to select DSR option.
ON* OFF Select the desire option(ON or OFF) for DSR signal. CTS OPTION <> CTS OPTION Press ENTER key to select CTS option. <<>> ON* OFF Select the desire option (ON or OFF) for CTS signal. DTE INTERFACE SELECT <> INF TYPE There are EIA530 or V.35 for Interface selection. <<>> EIA530* V.35* Use Left or Right key to select interface. E1 CONFIGURE MENU E1 SETUP This screen can configure the E1 parameter. Press ENTER to enter E1 Framing setup screen.
<> FRAMING Press ENTER to select E1 Framing. E1 FRAMING <<>> PCM31 CCS Press Left or Right key to select PCM31 CCS or PCM31 CCS CRC or PCM30 CAS CRC or UNFRAME. <<>> PCM31 CCS CRC <<>> PCM30 CAS <<>> PCM30 CAS CRC <<>> UNFRAME E1 INTERFACE SELECT <> INTERFACE Select the desire Interface for E1. The WireSpan 3000 provide RJ45 with 120 Ohm or BNC connector with 75 Ohm. Press ENTER to select.
<<>> 75 OHM COAXIAL <<>> DISABLE E1 HTU TYPE SELECT <> HTU TYPE Use this screen to select central or remote. Two connecting modems must be set to one central and the other remote, otherwise it will not connect. Press ENTER key to select. Use the Left or Right key to select then press ENTER to confirm.
IDLE CODE There are two idle codes for selection. Press ENTER to select. <<>> 7F* FF Use Left or Right key to select "7F" or "FF" idle code. E1 LINE CODING SELECT <> LINE CODING There are two methods of line coding. Press ENTER to select. <<>> AMI* HDB3 Use Left or Right key to select AMI or HDB3 line coding. AUXILIARY CONFIGURE MENU AUX This MENU configure the clock source, keylock functions.
<<>> E1 <<>> INTERNAL <<>> DTE KEYLOCK SETTING <> SET KEYLOCK This screen allows user to lock the four front panel keys. You must key in password before activate, the keylock function. Use Left or Right key to select keylock ON/OFF. <<>> ON OFF* KEYLOCK PASSWORD SETTING <> KEYLOCK PW The password contains ten numerical charactors. You must enter 10 digit of number.
TIMESLOT MAPPING (WireSpan 3000 ONLY) TS MAPPING The WireSpan 3000 provides drop & insert function. In this function , it allows user to asign every 64 kpps bandwidth to be used in DTE port. Please note that each HTU-C and HTU-R to be connected must be asigned in same Timeslot Mapping. X * 00 01 02 03 Select the desire timesolt and press ENTER to enter asign screen. Set to DTE to asign and set to IDL to unasign.
<> YES* NO Use Left or Right key to select YES then press ENTER. DIAGANOSTIC MENU TEST MODE Through the diagnostic, the user can separate and fix the communication problem. There are three loopback test. Detail test description will be found on Chapter 4. Local E1 and HDSL LOOP BACK <> LLB Press ENTER to activate the test. Press ENTER then Left or Right key to TEST MODE DISABLE screen to end test.
<< TEST MODE >> DISABLE PROFILE MENU [MAIN] PROFILE There are ten preset profiles for user to load, and five user profiles can be saved by user for later load. LOCAL PROFILE < PROFILE > LOAD 1 <> 2 3* 4 5 Use Left or Right key to select profile and press ENTER to load. SAVE PROFILE < PROFILE > SAVE There are five profile can be saved. <> 1 2 3* 4 5 Use Left or Right key to select profile and press ENTER to save.
There are ten factary default for user to load. Use Left or Right key to select and ENTER to load.
polling status, etc. Table 3-1 lists and describes the function of each key. Keys UP DOWN LEFT RIGHT ENTER (RETURN) Functions Exit to upper menu Enter menu or confirm your choice Select next left menu Select next right menu Refresh console screen and exit to upper menu Table 3-1 the function of each key Table 3-4 lists and describes the parameter of the console port. Please adjust familiar Terminal Emulator Software according to the Table 3-4.
CHAPTER 4 DIAGNOSTIC The WireSpan 3000/3000E supports a variety of loop back to assist you in isolating network problem. These tests can be used to analyze the HDSL line and the local and remote E1 HDSL performance. These tests can be initiated from the front panel. The following tests are available: z LLB: Tests the local E1 and DTE loop Local Side Data Equipment E1 HDSL The data block will be looped back at the local HDSL end of the WireSpan 3000/3000E to Verify the local circuit (E1 and DTE).
z HDSL RLB: (HTU-C mode only) This test examines transmit and receive circuit of the HTU-C and HTU-R and the HDSL loop. E1 HDSL HDSL HTU-C E1 HTU-R The data block will go through local WireSpan 3000/3000E (HTU-C) and loop back at remote HDSL end of the WireSpan 3000/3000E (HTU-R) to verify the local circuit and the HDSL line.
APPENDIX A SPECIFICATION HDSL LOOP INTERFACE Line Rate: 1168Kbps +/- 32ppm Line Code: 2B1Q Line Type: unconditional twisted pair Line Impedance: 135 Ohm Transmit Line: 13.5 +/- 0.5dB Range: 3.7Km for 26AWG 4.5Km for 24AWG Bit Error Rate: 1x10E7,or Better Connect: Rj-48C NETWORK INTERFACE Line Rate: 2.048Mbps +/- 32ppm Line Code: HDB3 Line Impedance: 75 Ohm for Coaxial Cable 120 Ohm for Twisted Pair Frame Format: Framed G.704 and Unframed G.
PHYSICAL DIMENSIONS Physical dimensions: 257mm in W x 266mm in L x 60mm in H POWER REQUIREMENT Input Voltage: 90 ~ 260 VAC 47~63 HZ(AC POWER) -36 ~ -72 VDC (DC POWER) ENVIRONMENT Temperature: 0°~50° Humidity: 0% ~ 95% non-condensing A-2
APPENDIX B DTE INTERFACE V.24 V.35 EIA530 EIA449 X.21 V.24 V.35 EIA530 EIA449 X.
DTE CABLE (M:Male F:Female): (1)SCSI(M) →V.24(F):1&7,2&3,4&5,6&20,8&24,15&17. (2)SCSI(M)→V.35(F):A&B,P&S,R&T,C&D,E&H,F&K,X&V, W&U,AA&Y,J&BB. (3)SCSI(M)→EIA530(F):1&7,3&16,2&14,12&15,9&17,4&19, 5&13,11&24,20&23,6&22,8&10,18&21,25. (4)SCSI(M)→EIA449(F):1&19,6&24,4&22,5&23,8&26,7&25, 9&27,17&35,12&30,11&29,13&31,10&14,18 (5)SCSI(M)→X.
HTU-C 2E1 1168 120 OHM HDB3 HDSL /FE1 MU:1.0 ROM:1.
LOOP STATUS <> L1:*** L2:*** CRC Error Count Far-End Block Error <> L1:*** L2:***dB Input Signal Level Far-End Signal Attenuation <> L1:*** L2:***dB Noise Margin * * * * 20 21 22 23 <> L1:*** L2:***dB * * * * 16 17 18 19 * * * * 24 25 26 27 C-2 M: minute H: hour ES: Error Second SES: Severely Error Secoud * * * * 28 29 30 31 CERR: CRC Erroe Count FEBE: Far-End Block Error SIGNAL LV: Input Signal Level LOS COND: LOS Condition FESA: Far-End.
* for WireSpan 3000 only << SETUP DTE>> CLKO POLARITY DTE << SETUP DTE>> DTE ACT STATE <<< CLKO INV>>> NORM* INV* <> FRAMING <> INTERFACK << SETUP DTE>> DATO POLARITY SH: Short Haul << SETUP DTE>> DSR OPTION << SETUP DTE>> CTS OPTION <<>> ON* OFF* <<>> PCM30 CAS CRC <<< DSR>>> ON* OFF* <<>> DISABLE <<>> PCM30 CAS <<< DCD>>> ON* OFF* << SETUP DTE>> DCD OPTION LH: Long Haul RLIU: Receive Line Interface Unit <<>> 7
AUX <> CLOCK SOURCE <> SET KEYLOCK <> KEYLOCK PW <<>> HDSL <<>> E1 <<>> OLD:********** <<4:HTU-R>> CAS+CRC 75 * for WireSpan 3000 only * * * * 24 25 26 27 <<>> DTE * * * * 20 21 22 23 <<>> INTERNAL * * * * 16 17 18 19 <> DISABLE * * * * 12 13 14 15 <> DLB <<3:HTU-C >> CAS+CRC 75 <> DTE IDL* <<2:HTU-R>> CAS+CRC 120 * * * * 08 09 10 11 <<>> NEW:********** * * * * 04 05 06 07 <>