User manual
User manual Version 1.0
SW5002 Wireless Serial Server
Copyright © 2007 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 23 -
Fig 27. COM port Information Web Page
5.5.1. Link Mode Settings
Click on the “Serial” link and the Fig. 27 screen will appear.
Fill in Serial parameter information on Serial Settings field
Click on “Save Configuration” button to save the changes.
5.5.2. TCP Server Mode
TCP Server mode is default Link mode of Serial Settings, and it can wait for connecting
requirement from remote host PC which running “serial-to IP” utility or setting SW5002s in tunneling
mode. User has to configure listening port to allow client establish connection to this server. Default
port number of SW5002 is 4660.
IP filtering function is a simple ACL (Access Control List). It can be disabled by setting FILTER_IP to
“0.0.0.0”.
User can configure one or group IP for source IP. If IP filter is enabled, only source IP assigned can
be connected to SW5002