- 37 -
Fig 43. TCP Server for Link Mode: Telnet
Operation: MainÆ [3]COM Port SettingÆ[1-16]Select PortÆ[1]Link ModeÆ[2]TCP Client
In the TCP Client mode, the device will actively make a TCP connection to any computer host. You need
to configure the designated computer hosts.
On “Destination IP” and “Destination Port”, enter the expected server IP address and its port number. The
SE5408/SE5416 Multi-Port Serial Server supports up to two destination hosts.
Fig 44. TCP Client Link mode by Telnet
Operation: MainÆ [3]COM Port SettingÆ[1-16]Select PortÆ[1]Link ModeÆ[3]UDP
The SE5408/SE5416 Multi-Port Serial Server can also operate in UDP mode, where the device will send
data packets to a set of hosts using UDP connection. The device can support up to 8 groups of IP
addresses for eight sets of the computer hosts.