User`s manual
User manual Version 1.3
SW5002 Wireless Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 4 -
3. Software Setup
Now the SW5002 hardware is installed and power is on, network IP configuration will be set in this
section.
3.1. Default Settings
The SW5002 has two IP addresses one for Ethernet interface and another one for wireless network
interface. These default settings are shown from under information
Default IP addresses
Interface Device IP Subnet mask Gateway IP
LAN port 10.0.0.50.100 255.255.0.0 10.0.0.254
WLAN Port 192.168.1.1 255.255.255.0 192.168.1.254
The other default settings of SW5002 are shown in the following table
Property Default Value
Ethernet Port
IP Address 10.0.50.100
Gateway 10.0.0.254
Subnet Mask 255.255.0.0
WLAN Port
IP Address 192.168.1.100
Gateway 192.168.1.254
Subnet Mask 255.255.255.0
Securit
y
User Name
Admin
Password
Null (Leave it blank)
Serial
COM 9600/None/ 8/1,No flow control, packet delimiter disabled
Link Mode TCP Server, Listen port 4660/4661,No Filter, Virtual COM disabled
SNMP
SysName of SNMP Name
SysLocation of SNMP Location
SysContact of SNMP Contact
Table 1. Default settings of the SW5002 device
NOTE: Press reset button for 5 seconds then release the button to restart SW5002 to the default
settings.
Waring: Please avoid setting LAN and WLAN IP address in the same subnet, that may make
unexpect networking problem.