vice versa. For example, the original RS-422/ RS485 bus data is transferred over the extended connected
distance by SW5002s, The destination IP is assigned by single IP or group IPs, The configuration is limited
by the Local Listening Port, default 4660 and 4661 on the COM1 and COM2 of SW5002.
SW5002 can support up to 4-group IPs for UDP connection, if users needed.
Fig 61. UDP mode in link mode
Note: In this phase, UDP mode does not support Virtual COM mode.
6.4.4. Serial Settings
Operation:
[Main] Æ [4 Serial Settings] Æ [2 Baud rate]/ [3 Parity]/[4 Data bits]/ [5 Stop bits]/ [6 Flow control]
User can configure baud ratedata bits, paritystop bit and type of flow control.
Fig 62. Serial Settings by Telnet
Note: The isolation one, SW5002-WgN1Sis (TB), only supported max 230Kbps baud rate.