SW5002 Wireless Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 34 -
SNMP Information:
SNMP Status: Enable [or Disable, Allows for changes in Networking Page]
SysName: [Allows for changes in Networking Page]
SysLocation: [Allows for changes in Networking Page]
SysContact: Allows for changes in Networking Page]
Serial Information:
UART mode RS485/RS232/RS422
Link Mode: TCP Server [or TCP Client/UDP Mode, Allows for changes in Serial Page]
Baud rate: 115200 [or 1200/2400/4800/9600...Allows for changes in Serial Page]
Parity: None [or Even/Odd/Space/Mark...Allows for changes in Serial Page]
Data bits: 8 [or 7 (bits).Allows for changes in Serial Page]
Stop bits 1 bit or 2 bits
Flow Control None, Xon/Xoff, RTS/CTS
6.2. Networking Configuration
Operation: [Main]Æ[2 Networking]:
Select “2” on “Input choice (0~6) and enter:” to enter Networking settings page.
Fig 41. Networking Settings by Telnet
Note: Press “0” key to return to the previous menu
This section allows for changes in IP address, subnet mask, gateway IP address and SNMP information.
Please note that setting changes will not take effect until the SW5002 is restarted.