5.5.4. UDP Mode
SW5002 can be configured in a UDP mode to establish connection using Unicast or Multicast data from
the serial device to one or multiple host computers. Vice versa is also true. For example, the original
RS-422/ RS485 bus can be transferred and extended connected distance by SW5002s.
The destination IP is assigned by single IP or group IPs, The configuration is limited by the Local Listening
Port. For example, on SW5002 listening port is 4660 which receive data sending from the host computers.
SW5002 can support up to 4-group IPs for UDP connection, if users needed.
Fig 30. UDP protocol in Link mode
Note: In this phase, UDP mode does not support Virtual COM mode.
5.5.5. Serial Settings
This filed can be configured with serial parameters for SW5002. Here User can configure Serial parameters,
include UART Mode, baud rate, parity, data bit and type of flow control.
Configure UART Mode: RS-232 or RS-485 or RS-422
Baud rate: 1200/2400/4800/9600/19200/38400/57600/115200
Parity: None or Odd or Even or Mark or Space
Data bits: 7 or 8
Stop bits: 1 or 2
Flow control: None or Xon/Xoff or Hardware (RTS/CTS).
Fig 31-1. Serial Communication Settings from Web Page
Note: The isolation, SW5002-WgN1Sis (TB), only support max 230Kbps baud rate.