User`s manual
User manual Version 1.3
SW5002 Wireless Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 6 -
Note: ARP commands can only be used to set a static IP address of SW5002
- arp –a command show the current mapping IP and MAC addresses.
- arp –s “IP address” “MAC address” map the IP address to specify MAC address.
3.2.2. Configure IP by web interface
Use common Web browser, ex. Microsoft Internet Explorer or Mozilla Firefox, to configure the network
parameters of SW5002.
Open web browser, type in the IP address (default IP: 10.0.50.100) of SW5002 to be configured.
Default user name is admin and default password is null (leave it blank).
Configure IP settings from web Network links page then click “Save Configuration” to save
settings.
Click on ”Restart” button to make the change effective.
Please refer to contents of Web Configuration section
for more details.
.
3.2.3. Configure IP by Telnet utility
Use common Telnet utility, ex. Microsoft Hyper-terminal, to configure the network parameters of SW5002.
Run command telnet “IP address” to telnet to SW5002 . Default IP address is 10.0.50.100 and
default password is null (leave it blank).
Configure IP settings from network settings menu, and restart system after saved settings.
Please refer to Telnet Configuration
section for more details.
3.2.4. Auto IP with DHCP
DHCP server will automatically supply an IP address gateway address, and subnet mask to SW5002. By
default, the DHCP client function on SW5002 is disabled, user can activate the DHCP functions by the
following steps
Execute SerialManager Utility
Click on the IP address (of SW5002)
Click “Config” to pop-up the static IP Dialog Window
Check on ”Auto IP”
Click “Config Now” (The SW5002 will restart and obtain the IP from the DHCP server
automatically)
3.3. TCP/IP Port Number
Default Port numbers of SW5002 is 4660 (1
st
port) & 4661 (2
nd
Port) and it is associated with the serial port
COM1 and COM2 respectively. After the application program connected to the TCP port 4660 (or 4661) on
the SW5002, data of user’s application program are transmitted transparently to SW5002 and vice versa.