User`s manual

Quick Start Guide Version 1.3
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
3
Figure 3.
1. monitor.exe utility Dialog Window
Assign a Static IP address by:
A. Using Telnet
1. Telnet to SE5001 using DOS command “Telnet IP_address”. Example: telnet 10.0.50.100
2. SE5001’s network, link mode and COM ports settings can be configured in the telnet window
B. Using Monitor.exe Utility
Use Monitor.exe which comes inside the Product CD to automatically search for all SE5001
connected to ones local area network. Then please select the desired SE5001 to configure the
network setting individually.
C. Using Web Browser
1. Make sure ones PC is located on the same network sub-net as SE5001
2. 2Open a web browser, then type in the IP address of SE5001 to be configured. Default user
name is admin and default password is null (leave it blank).
3. 3SE5001’s network, link mode and COM ports settings can be configured in different web pages.
4. Click Save Configuration” to save settings.
5. Click Restart” button to make the change effective if necessary.
4. Pin Assignments
The pin assignments of DB9 connector on SE5001 is shown in the following table:
Pin#
RS-232
Full Duplex
for SE5001-S2 Model
RS-485 2-wire
Half Duplex
for SE5001-S5 Model
RS-422/RS-485 4-wire
Full Duplex
for SE5001-S5 Model
1 DCD N/A N/A
2 RXD N/A TXD+
3 TXD DATA+ RXD+
4 DTR N/A N/A
5 SG (Signal Ground) SG (Signal Ground) SG (Signal Ground)
6 DSR N/A N/A
7 RTS DATA- RXD-
8 CTS N/A TXD-
9 N/A N/A N/A
Customer Services and Supports
1. Contact your local dealers or Atop Technical Support Center at the following numbers.
y +886-3-550-8137 (Atop Taiwan)
y +86-21-6495-6232 (Atop China)
2. Report the errors via Atop’s Web site or E-mail account
www.atop.com.tw
, service@atop.com.tw
www.atop.com.cn
, service@atop.com.cn