User`s manual
User Manual Version 1.4
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
26
Figure 3.21 Com1 setup-TCP server
Note:
1. Default Port number of SE5001 is 4660 and it is associated with serial port COM1 respectively. After
ones application program connects to the TCP port 4660 of SE5001, data being sent to this TCP
connection from ones application program are transparent to the COM1 of SE5001. Vice versa is
also true.
2. The serial interface will show different port interface according to the model of the serial server.
3.3.5 Configure SE5001 as TCP Client
Configure SE5001 as TCP client, for example the destination IP is 10.0.29.11, destination port is
4660 .( Figure 3.22)
Input destination IP “10.0.29.11”
Input destination port in the “4660”
Input idle time in “Please input idle time to send TCP alive packet ( sec)
:
”(If one input 4->the
sending TCP keep alive packet period will be change to 4*10 sec)
1. Select “TCP Connect On Power-on”:to keep trying to establish TCP connection after Power on
2. Select “TCP Connect On Any Serial Character”:Any serial character will trigger to establish the
TCP connection
Input idle time to disconnect in the “Serial Inactivity Time before disconnect(0sec , 1~255)
:
” (If
one input 0->disable the function; if one input 2 ->the serial Inactivity beyond 2 sec will cause
disconnect)
Input error retrying time in “Waiting Time Between Re-connect Attempts(0 minute,1~255)
:
” (If
one input 0->disable the function; if one input 2 ->the serial Inactivity beyond 2 sec will cause
disconnect)
Click on “Save Configuration” button to save the changes