User`s manual

User Manual Version 1.4
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
18
3.2.5 Configure SE5001 as TCP Client
Type 2 in the “Input choice(1~5) and enter“(Figure 3.11)
Input destination IP in the “Please input Destination IP
Input destination port in the “Please input Destination port
1.Type 1 for Connected always
Double click “Enter” key
Input idle time in “Please input idle time to send TCP alive packet(4*10sec)”(If one input 2->the
sending TCP keep alive packet period will be change to 2*10 sec)
2.Type 2 for Trigger by receiving COM port data
Input idle time to disconnect in the “Please input idle time to disconnect(0sec , 1~255)” (If one
input 0->disable the function; if one input 2 ->the serial Inactivity beyond 2 sec will cause
disconnect)
Input error retrying time in “Please input waiting time for error retrying(0 minute,1~255)” (If one
input 0->disable the function; if one input 2 ->the serial Inactivity beyond 2 sec will cause
disconnect)
Double click “Enter” key
Input idle time in “Please input idle time to send TCP alive packet(4*10sec)”(If one input 2->the
sending TCP keep alive packet period will be change to 2*10 sec)
Figure 3.11 Link Mode-TCP client setup