17
The page gives one the opportunity to configure parameters of COM1 setting which include COM1 working
mode, port parameters, enabling or disabling serial buffer’s data and setting packet delimiter.
LINK Mode Setup Configure SE5001 as TCP server(Figure 3.10)
Type 1 from “Input choice and enter (1~4):” of COM1
Type 1 in the “Input choice(1~5) and enter
Input local port in the “Please input local port
1.If one want to enable IP filter
Input y in the “Do one want to enable IP filter(y/n)?
Input source IP in the “Please input Filter_IP
Double click “Enter” key
2.If one don’t want to enable IP filter
Input n in the “Do one want to enable IP filter(y/n)?
Double click “Enter” key
Input idle time in “Please input idle time to send TCP alive packet(4*10sec)”(If one input 2->the
sending TCP keep alive packet period will be change to 2*10 sec)
Note:
1. IP filtering function is disabled if setting FILTER_IP to “0.0.0.0”.
2. IP filter is disabled by default
3. If IP filter is enabled, only source IP assigned can connect to SE5001.
Figure 3.10 Link Mode-TCP server setup