User`s manual
User Manual Version 1.4
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
10
2.1 LED Indicators
2.1.1 LAN LED
Message Description
Off
Ethernet Disconnected
Blinking with Green
Data is transmitting on Ethernet for 100Mbps
Blinking with Orange
Data is transmitting on Ethernet for 10Mbps
Table 1. LAN LED Message
2.1.2 COM Port LED
Message Description
Off
No data is transmitting on COM port
Blinking
Data is transmitting on COM port
Table 2. COM Port LED Message
2.1.3 RUN LED
Message Description
On Jumper JP1 Pin1 and Pin2 are shorted to disable
AP firmware running
Blinking (rate: 0.5 Sec) AP firmware is running normally
Table 3. RUN LED Message
2.2 Installation Procedures
Step 1: Connect SE5001 to power source using 5V DC Jack
(or 9~30V DC Terminal Block power source)
Note:SE5001 provide two power inputs can be connected simultaneously to live DC
power sources. Anyone of the power inputs fails, the other live source acts as a backup
to support power needs automatically. The redundant dual DC power inputs give one
extra assurance of non-stop operation
Step 2: Connect SE5001 to ones Ethernet network. Use a standard straight-through Ethernet cable
when one connect it to a hub/switch, one also can connect it to ones PC‘s Ethernet port via a
cross-over Ethernet cable for easy set up. However, in this case one need to make sure ones PC is in
the same network sub-net as SE5001.
Step 3: Connect SE5001’s serial port to a serial device.
Step 4: Placement options. One can mount SE5001 to a wall/panel (Mounting screws included) or
Din-Rail rack (Require optional item model: Din-Rail-Kit DK-25).