D.3 Configuring Devices
Use monitor.exe to configure the settings of devices on the network.
1. Repeat the steps in D.2 to bring up devices information.
2. Select the device to be configured from IP Address. Click on the “Config button, a configuration dialog
box will popup as shown in Fig. 45:
Fig. 45. Configuration dialog box
3. After clicking on the “Configure Now” button, the target device returns an “ACK” message, indicating the
modification is successful as shown as follows:
The following table lists the functional description for each field.
Field Name Field Descriptions
Broadcast IP
Except for the default IP 255.255.255.255, other items (IPs) are read from the file
“seg.cfg”. This field specifies a detecting IP range. It may be a designated IP or a
broadcast IP.
Wishes
Specifies minimum number of the devices one wish to get reply from after sending
an Invite request. If there is not as many as devices responding to ones invitation,
the system repeatedly sends invitation until ones request is fulfilled.
Reply
Indicates the actual number of devices this utility program detected.
Retry
Specify the number of times that an Invite request is re-sent.
Locate
Locate the specified device.
Reset
Reset the selected device.
Config
Configure the selected device.
Exit
Exit this utility.