Hex File End of Record Error
SE5002
handshaking problem
SE5002 ACK Start Address Error
SE5002 ACK Length Error
SE5002 Response Command Error
Configuration file Remote IP not found
Open configuration file failure
APPENDIX C: RE-LOADING SYSTEM FIRMWARE
The AP (application program) firmware of SE5002 can be disabled If a wrong version is downloaded.
To disable the current version of firmware and re-load the correct one, do the followings:
1. Turn power off, open SE5002 case.
2. Short pin1 to pin2 on jumper JP1 (on the right-top corner of the main board) to disable the current AP
firmware.
3. Turn SE5002 power on.
4. Download the correct AP firmware. .
5. Open pin1 and pin2 on jumper JP1 to enable AP firmware.
6. Close the case and continue operations.
APPENDIX D: RUNNING MONITOR.EXE UTILITY
The configuration utility monitor.exe is the main utility program used to display and to configure SE5002
settings.
D.1 Running Monitor.exe utility
Start the program under Windows 98/NT/2000 environment and the following window shall appear(Fig. 44).
Fig. 44. Main window of monitor.exe utility program
D.2 Detecting Operational Devices
Follow steps below to detect all devices currently available on the network.
1. Start monitor.exe utility program.
2. Select an item from the Broadcast IP list.
3. Specify a number on Wishes box.
4. Click on the Invite button. This will display all the devices requested.