User`s manual

User manual Version 1.1
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
- 41 -
COM1(2) RX LED on blinking state
Data is receiving on COM port
Table 3. COM Port LED Message
A.4.4 RUN
Message Description
LED on Jumper JP1 pin1 and pin2 are shorted to disable AP firmware in
the flash memory.
LED blinking (rate: 0.5Sec) AP firmware is running
Table 4. RUN LED Message
A
PPENDIX B: UPGRADING SYSTEM FIRMWARE
New version of firmware can be downloaded from www.Atop.com.tw
B.1 System Upgrading Procedure
1. Make sure the PC and the SE5002 are on the same network. Use command ping or monitor.exe utility
program to verify their availability.
2. Prepare the download tool and press any key to edit the configuration file dapdl.cfg.
3. Edit "dapdl.cfg" to fit the system requirements, the contents of the file shall look like the following
window. Be sure to save your modifications.
Remote_IP 10.0.50.100
Load U5002.hex
The first line identifies the IP address of SE5002; the second line identifies the firmware (.Hex file) name
to be downloaded.
4. Run download.bat.,.
5. Input user name and password credential to begin new firmware download.