User`s manual

User manual Version 1.1
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
- 26 -
host computer to a serial device.(Fig. 32)
NotesThe configuration is limited by the Local Listening Port (For example, on the SE5002 listening the port
is 4660 which receives data from the Host Computer).
HUB
TCP/IP Network
Host Computer #1
IP: 192.168.1.3
Destination IP 192.168.1.1
Destination Port 4660
Host Computer#2
IP: 192.168.1.100
Destination IP 192.168.1.1
Destination Port 4660
Host Computer #3
IP: 192.168.1.200
Destination IP 192.168.1.1
Destination Port 4660
Host Computer #4
IP: 192.168.1.254
Destination IP 192.168.1.1
Destination Port 4660
Serial Device 1
Serial Line
SE5002
IP 192.168.1.1
Listening port 4660
UDP datagram
Fig. 32. Data Transmission in a UDP Slave(server) Mode
3.4 Assigning new IP Address with ARP commands
ARP (address resolution protocol) commands can be used to assign a static IP address on SE5002 using
its hardware MAC (media access control) address. The MAC address"0060E9-xxxxxx" is printed on the rear
side of device . The following shows how it works on MS-DOS command prompt window.
Example: change IP from 10.0.50.100 to 10.0.50.101,and MAC address being 00-60-e9-11-11-01
Step1: Add the new host IP to the ARP table
Open Ms-DOS command prompt window
Input arp -s 10.0.50.101 00-60-E9-11-11-01(Fig. 33)
Fig. 33. Ms-DOS command prompt window: add host computer IP to ARP table
Step2: Change to the new IP via Telnet port 1(Fig. 34)
Input telnet 10.0.50.101 1
NoteTelnet will fail and then SE5002 restarts automatically. Afterward, the new IP address is changed to
10.0.50.101
Step3: Using the new IP to configure SE5002 via Telnet
Input telnet 10.0.50.101
Note:
1. Both PC's IP and SE5002 's IP must belong to the same subnet.
2. The changed IP address must be legal; otherwise it will change back to the default value (10.0.50.100)
after restart.