- 21 -
Click on “COM1” link and the following screen shall appear.
Configure SE5002 as TCP server
Input local listening port “4660
1.To enable IP filter
Check “IP filter
Input source IP on “Source IP”
2.If not to enable IP filter
Don’t check “IP filter
Input idle time on “Please input idle time to send TCP keep-alive packet(sec)
”( 2->the sending
TCP keep-alive packet period will be 2*10 sec)
Input TCP Inactivity time in “TCP Inactivity Time Before Disconnect( sec)
”( 2->TCP Inactivity
beyond 2 sec will cause disconnect )
Click on “Save Configuration” button to save the changes
Notes:
1. One may configure COM1 or COM2 parameter by choosing COM1 or COM2 Link
2. IP filtering function is disabled by setting FILTER_IP to “0.0.0.0”.
3. IP filter is disabled by default
4. If IP filter is enabled, only source IP assigned is connected to SE5002.