User’s Manual Atop ABLELink® SE5002 Series 2-Port Ethernet Serial Server Version 1.2 Updated on 2007/03/15 Tel: 886-3-5508137 Fax: 886-3-5508131 www.atop.com.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 IMPORTANT ANNOUNCEMENT The information contained in this document is the property of Atop Technologies, Inc. and is supplied for the sole purpose of operation and maintenance of products of Atop Technologies, Inc.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 This document is intended to provide customers with brief descriptions on the product and to assist customers to get started. For detail information and operations of the product, please refer to this manual or the CD attached. FCC WARNING Class A for Ethernet Serial Server (Model SE5002 series) This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 CONTENTS 1 INTRODUCTION...........................................................................................................................7 1.1. PACKAGING....................................................................................................................................7 1.2. MODES OF OPERATION...........................................................................................................7 Fig. 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 19. Com port-Enabling serial data buffer.............................................................................17 Fig. 20. Setting packet delimiter timer ........................................................................................18 Fig. 21. Setting packet delimiter-character pattern .....................................................................18 3.3 Configuring Using Web Browser............................
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 4.1.4 Installation.................................................................................................................................28 4.1.5 Uninstalling...............................................................................................................................28 4.2 Virtual COM communications .................................................................................................... 28 4.2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 A.3.2.2 Terminal Block Pin Assignments ..........................................................................................39 A.3.3 Ethernet Port (RJ-45) Pin Assignments ...................................................................................39 Note: Device will not be damage if the polarity is reverse................................................................40 A.4 Buzzer/LED Message ....................................
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 1 INTRODUCTION Many industrial and Commercial devices equipped with slow serial communication ports RS-232, RS-485, and RS-422 are limited in their transmission distance of 15 m. Examples of these devices are PLC controllers, card readers, display signs, security controls, CNC controller, etc. ATOP Technologies has overcome the limit with a family of SE 5002 Series Ethernet Serial Servers.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 TCP Client Mode:SE5002 can be configured in a TCP client mode on a TCP/IP Network to actively establish a connection with an applications server –the host computer. After the connection is established, data can flow in both directions (Fig 2 TCP Client Mode). Fig. 2. TCP Client Mode UDP Mode:UDP is a fast but non-guaranteed datagram delivery protocol.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Tunneling Mode(Pair Connection):The tunneling mode is used for multiple serial devices to “talk” to each other through SE 5002’s and their Ethernet connections (Fig 4 Tunneling Mode). This mode is particularly useful when two serial devices are far away, because their communication distance is limited to 15 m. Fig. 4. Tunneling Mode 1.3. Hardware Description NOTE: 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Blinking Green Blinking Orange 2.1.2 Data transmitting on Ethernet at 100Mbps Data transmitting on Ethernet at 10Mbps Table 1. LAN LED Status COM Message Off Com1(2)TX Blinking Com1(2)RX Blinking Description No data transmitting on COM port Data transmitting on COM port Data receiving on COM port Table 2. COM Port LED Status 2.1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 6. Configuring the static IP with monitor.exe utility Fig. 7. Static IP dialog window A DHCP server can automatically assign the IP address and all the network settings, and SE5002 supports the DHCP client functions. By default, the DHCP client function on SE5002 is disabled; one may activate the DHCP client functions by the following steps: Execute Monitor.exe(Fig.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 for a password, the default password is Null (Leave it blank). (Fig. 9) Fig. 9. Telnet to the system Note: One may press the reset button to reset the password.. 1 Then the following main menu shall appear (Fig. 10) Fig. 10. System main menu Notes: 1. If the SE5002 does not receive any command within 1 minute, Telnet will be terminated automatically. 2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 and AP version, and the connection status of the device. Select “2” on “Input choice and enter (0~5):” to enter Networking window (Fig. 12). Fig. 12. Network configuring using Telnet This screen allows for changes in IP address, subnet mask, gateway IP address and SNMP information. Please note that setting changes will not take effect until the device is restarted. Note: Press “ESC” key to return to the previous menu . 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Note: One may press the Reset key on the product to reset password. Select “4” on “Input choice and enter (0~5):” (Fig. 14). Fig. 14. Com1 setup Here one may configure COM1 parameters, include COM1 operation mode, port parameters, enabling or disabling serial buffer’s data and packet delimiter. LINK Mode Setup Configure SE5002 as TCP server:(Fig.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 15. Link Mode-TCP server setup Enter 2 on “Input choice(1~5) and enter:”(Fig. 15) Input destination IP on “Please input Destination IP:” ( for instance: 10. 0. 29. 123) Input destination port on “Please input Destination port:”( for instance: 666 ) 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 16. Link Mode-TCP client setup In this example the local port is 4660; the destination IP is 10.0.29.254, and the destination port is 666(Fig. 17) Fig. 17. Link Mode-UDP client setup Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Enter 2 on “Input choice and enter (1~5):” of COM1, the following screen shall appear; then proceed to assign the COM port alias, set baud rate and parity, determine number of data bit and stop bit, and decide on the need of flow control (Fig. 18) Fig. 18.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 20. Setting packet delimiter timer One may also choose character pattern as the packet delimiter indicated in Fig. 21 Fig. 21. Setting packet delimiter-character pattern SE5002 also is designed to accept serial control commands directly over Ethernet following the RFC2217 format. For more detail ,contact our Technical Support. 3.3 Configuring Using Web Browser 1. 2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 22. login the system via Web 3 The following overview screen shall appear (Fig. 23) Fig. 23. Overview 3.3.2 Changing password 1. Click on the “Security” link and the following screen shall appear (Fig. 24) Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 24. Change the password 2. Enter the old password on “Old Password” field; enter the new password on “New Password” and the “Verified Password” fields, and then click on “Save Configuration” to update the password. Note: One may press the reset key on the product to reset password to the default value. 3.3.3 Networking Click on “Networking” link and the following screen (Fig. 25) shall appear. Fill in IP information on the TCP/IP field.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Click on “COM1” link and the following screen shall appear. Configure SE5002 as TCP server Input local listening port “4660” 1.To enable IP filter: Check “IP filter” Input source IP on “Source IP” 2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 26. Com1 setup-TCP server Notes: 1. Default COM1 of SE5002 is 4660 (COM2 is 4661) and it is associated with the serial port COM1 or COM2. After the application program being connected to the TCP port 4660 on the SE5002, data of ones application program are transparent to both COM1 and SE5002. 2. The serial interface may have different port interfaces for different models. 3.3.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 27. Com1 setup-TCP client 3.3.6 Pair Connection(Tunneling Mode) Pair connection is for two or more serial connections with their own SE5002’s to send data over Ethernet to communicate with each other. To do so, choose “pair connection” indicated in Fig. 28 Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 28. Com1 setup –pair connection 3.3.7 Configuring SE5002 in UDP mode: SE5002 can be configured on a UDP mode to establish connection using unicast or broadcast data from the serial device to one or multiple host computer. Vice versa is also true. There are 2 UDP communication Modes: 1. Master (Client) Mode:To establish a connection using unicast or broadcast data from the serial device to one or multiple host computer.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 29. Com 1 setup –UDP mode On “destination IP” enter 10.0.255.255 “ On “destination port “ enter 666”. On “Local port “ enter 4660”. Click on “Save Configuration” to save the changes. Note:If the update is successful, the following screen shall appear (Fig. 30) Fig. 30. Configuration successfully updated SE5002 IP 192.168.1.1 Destination IP 192.168.1.255 Destination Port 666 TCP/IP Network Host Computer #1 IP: 192.168.1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 host computer to a serial device.(Fig. 32) Notes:The configuration is limited by the Local Listening Port (For example, on the SE5002 listening the port is 4660 which receives data from the Host Computer). SE5002 IP 192.168.1.1 Listening port 4660 TCP/IP Network Host Computer #1 IP: 192.168.1.3 Destination IP 192.168.1.1 Destination Port 4660 Serial Line Serial Device 1 HUB Host Computer#2 IP: 192.168.1.100 Destination IP 192.168.1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 34. Assigning a new IP address with ARP command 4. USING VIRTUAL COM Virtual COM driver mode for windows converts COM data to LAN data for control of the COM port on SE5002 via LAN. By creating virtual COM ports on the PC, the Virtual COM driver redirects the communications from the virtual COM ports to an IP address and port number on a SE5002 that connects the serial line device to the network. Fig.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 ․ Operation system: Windows Server 2003, Windows XP, Windows 2000, Windows NT 4.0 SP5 or later, Windows Me, Windows 98, Microsoft NT/2000 Terminal Server, Citrix MetaFrame 4.1.2 Cautions on Use The Virtual COM driver supports firmware AP v3.0 or later for the SE5002 Ethernet Serial Server. 4.1.3 Limitation The Virtual COM driver provides users with up to 256 Virtual COM ports. Users may select from COM1 to COM256. 4.1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Fig. 37. Enabling Virtual COM port via Telnet 4.2.2 Running Serial/IP on monitoring PC On Window Start Menu, go to \program\serial/IP for ATOP\control panel\Select Port\, then select the serial port. Then the “ Serial I/P for Atop Control Panel” window appears (Fig. 38). Fig. 38. Serial/IP for Atop control panel On the right of the panel is a sample for COM 4 settings.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 been selected (on Select Ports window) for use by the Virtual COM Redirector. Change the list by clicking the Select Ports button. Each COM port has its own settings. When click on a COM port, the Control Panel changes to reflect that the selected port. Note: COM port changes become effective immediately. 4.3 Configuring Virtual COM Ports Serial/IP COM port can be changed as follows:(Fig. 39) 1. Select a COM port on the list. 2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 5. SNMP SETUP 5.1 SNMP Network Management Platform SE5002 is an SNMP device that allows many popular SNMP Network management platforms such as HP OpenView and SunNet Manager, to conduct monitoring on the device. Depending on the network management tools used, SE5002 information can be collected from running the management tools, including IP address, DNS name, system descriptions and NIC information. 5.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 below (Fig. 42) 4 Fig. 42. NetworkView display the devices found Double-click on the device icon to display information about the device, including IP Address, Company, SysLocation (Max 15 characters), SysName (Max 9 characters) and types etc (Fig. 43). Fig. 43. NetworkView display device information Notes: 1. NetworkView is limited to information extracting and viewing only. 2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 6.1 Preparing System 1. Connect SE5002 to power, Ethernet and serial cables 2. Configure SE5002: connection type, IP address, gateway IP address, and network mask (see chapter 3 Hardware Installation). 3. Configure SE5002 as TCP Server, using the default TCP port number 4660. 4. The host (PC) application program must be configured as a TCP client and connected to SE5002 with designated TCP port number 4660 for COM1. 5.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 TCPTEST2 IP_Address Port_Number The command tcptest2 10.0.50.100 4660 connects a TCP server of IP address 10.0.50.100 to port number 4660. The received data is displayed on the screen and the input data is sent to the TCP server. Binary data in hex format with a leading character “\” can also be sent. For example, “\00” and “\FF” represent ASCII code 0 and 255, respectively. A modem can also be used to connect to the serial server.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 Status Descriptions The system is configured as a TCP Server and Listing. S The TCP Server is connected. A The system is configured as a TCP Client and not yet connected. C The system is configured as a TCP Client and trying to Connect. C The TCP Client is connected. B The system is configured as an UDP Mode. U For example, ‘S’ means that COM1 is in server mode and is not connected. 7.3 Using TCPTEST.EXE or TCPTEST2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 LED indication 4) Stop bits: 1,2 5) Packet Delimiter: by inter-character timeout, by characters delim 6) Flow Control: None, Hardware CTS/RTS, Software Xon/Xoff RUN x 1 LAN x 1 COM port x 4 Power Requirement +9~30VDC Jack or DC +9~30V Terminal Block, 2.8 Watt Max Temperature Operation: Storage: Humidity 20%~90% non-condensing Housing 90mm(L) x 45mm(W) x 63mm(H) 0℃ to 60℃ -20℃ to 70℃ Copyright © 2006 Atop Technologies, Inc.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 A.2. Software Specification Item Protocol Configuration Internal Buffer Size Specifications TCP, UDP, ARP, ICMP, SNMP, HTTP, Telnet, BOOTP, DHCP Configuration information for both TCP/IP and serial ports is written in the EEPROM. Configuration utilities of Windows 98/2000/NT/XP/2003 are provided.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 A.3.2.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 A.3.2.2 Terminal Block Pin Assignments The pin assignments of Terminal Block connector on SE5002-S55is are shown in the following table: RS-485/RS-422 RS-485 Pin# 4 wire, Half Duplex 2 wire, Full Duplex For SE5002-S55is For SE5002-S55is 1 2 3 4 5 T+ T- NC NC R+ RSG (Signal Ground) Data+ DataSG (Signal Ground) A.3.3 Ethernet Port (RJ-45) Pin Assignments 1. Category 5 UTP cable, 8 core wire. 2. RJ45 Connector. 3.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 F.G. VIN- VIN+ Note: Device will not be damage if the polarity is reverse. A.4 Buzzer/LED Message A.4.1 Buzzer “ ^ “: Beep twice “ = “: Beep off Message Description ^===^===^===^===^===^===^... Watchdog problem, return service is required (1sec) ^^^^^^^^^^^^^^^^^^^^^^^...
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 COM1(2) RX LED on blinking state Data is receiving on COM port Table 3. COM Port LED Message A.4.4 RUN Message Description LED on Jumper JP1 pin1 and pin2 are shorted to disable AP firmware in the flash memory. LED blinking (rate: 0.5Sec) AP firmware is running Table 4. RUN LED Message APPENDIX B: UPGRADING SYSTEM FIRMWARE New version of firmware can be downloaded from www.Atop.com.tw B.1 System Upgrading Procedure 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 6. SE5002 will automatically restart after downloading. B.2 Critical Issues 1. The upgrading process can be aborted by pressing the key. SE5002 will restart automatically and the system remains the same. 2. If SE5002 does not receive any upgrading data within 30 seconds, it will restart automatically and the system remains the same. 3.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 SE5002 handshaking problem Configuration file Hex File End of Record Error SE5002 ACK Start Address Error SE5002 ACK Length Error SE5002 Response Command Error Remote IP not found Open configuration file failure APPENDIX C: RE-LOADING SYSTEM FIRMWARE The AP (application program) firmware of SE5002 can be disabled If a wrong version is downloaded. To disable the current version of firmware and re-load the correct one, do the followings: 1.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 D.3 Configuring Devices Use monitor.exe to configure the settings of devices on the network. 1. Repeat the steps in D.2 to bring up devices information. 2. Select the device to be configured from IP Address. Click on the “Config” button, a configuration dialog box will popup as shown in Fig. 45: Fig. 45. Configuration dialog box 3.
User manual Version 1.1 ABLELink® Ethernet Serial Server SE5002 IP Address MAC Address Gateway Subnet Mask OS AP Version Model Indicate the IP address of the device that replied to ones request. Leading tag “!” stands for IP address collision, possibly caused by duplicated IP addresses on the network. Leading tag “?” stands for Mac address collision, possibly caused by duplicated Mac addresses on the network. Indicates the MAC address of responding device. Indicates the IP address of the gateway.