User`s manual

User manual Version 1.0
ABLELink
SW5001 Wireless Serial Server
38
4.4.7. Configuring Serial setting
This filed can configure serial parameters for SW. Here one may configure Serial parameters, include
UART Mode, baud rate, parity, data bit and type of flow control you wanted
Configuring UART Mode: RS-232 or RS-485 or RS-422
Baud rate: 1200/2400/4800/9600/19200/38400/57600/115200
Parity: None or Odd or Even or Mark or Space
Data bits: 7 or
Stop bits: 1 or 2
Flow control: None or Xon/Xoff or Hardware(RTS/CTS)
Fig. 56. COM settings from Serial Web Page
4.4.8. Configuring packet delimiter
Packet delimiter is a way of controlling the number of packets in a serial communication. It is designed to
keep packets in track. SW provides two ways in parameter setting: (1) Packet delimiter timer and (2)
Character patter terminator. By default, packet delimiter timer is 10 ms. the range of packet delimiter timer
is 10 to 30,000 msec, if “character patter is selected, for a data stream ended with “0x0a04”, then the
entire data buffer of the serial device is transmitted.
One may also choose character pattern as the packet delimiter indicated.