User`s manual

User manual Version 1.0
ABLELink
SW5001 Wireless Serial Server
5
This mode can be used to extend the normal serial communication distance of 15 m to 100 m or longer.
SW can be configured to the TCP Server Mode and waits for the host computer to establish a connection
with a serial device (the client). After the connection is established, data can flow in both directions (also
see Chapter 錯誤! 找不到參照來源。 錯誤! 找不到參照來源。) , and hence enables two or more serial
devices to communicate with one another over IP network.
TCP –Server & Client
One may establish a connection between a TCP Server and a TCP Client for Master /Slave PLCs or other
serial devices.
Fig. 5. TCP Link in Tunneling mode
Configuring SE Series to Tunneling Mode
Using one of the four configuration methods (Telnet, Web, console and LCM controller), one may configure
SW to TCP Server mode with a listening 4660 port, and with other serial servers configured as TCP
Clients
TipTCP server shall assign the destination IP and the destination port corresponding to TCP client’s
listening port (example: TCP 4660 port).