User manual

User manual Version 1.1
ABLELink
Serial-Ethernet Server
GW51W-
MAXI
Copyright © 2003 Atop Technologies, Inc.
Run-time
When run-time, if the default key is pressed and then released, one of the specified actions will be down
depending on the released time after you heard how many beeps.
State 1. When run-time, if the key is pressed, there is 1 clear beep and then silence.
If key is released here, system will restart.
State 2. After state 1 for 3 seconds, there are 2 clear beeps.
System will restore default configuration and then restart.
State 3. After state 2 for 30 seconds, there are 3 clear beeps.
The action is the same as State 3 in startup time.
State 4. After State 3 for 3 seconds, there are 4 clear beeps.
The action is the same as State 4 in startup time.
State 5. After 4 for 3 seconds, there are 5 clear beeps.
The action is the same as State 5 in startup time.
State 6. After state 5 for 3 seconds, there is 1 clear beep.
The action is the same as State 6 in startup time.
BSS quality is indicated by count of beeps, which is shown as bellowed:
1 beep There is no signal detected
2 beeps The quality is between is 0%~20%
3 beeps The quality is between is 20%~40%
4 beeps The quality is between is 40%~60%
5 beeps The quality is between is 60%~80%
6 beeps The quality is between is 80%~100%
A.5 LED indicator
LAN LED
Message
Description
LED Off
No data is transmitting on Ethernet
LED blinking
Data is transmitting on Ethernet
Table 2. LAN LED Message
COM Port LED
Message Description
LED off
No data is transmitting on COM port
All rights reserved. Designed in Taiwan.