GW21W will automatically restart each time the firmware is successfully downloaded.
B.2 Critical Issues of Upgrading
1. You can always abort the upgrading process by pressing the <Esc> key from host PC during the
upgrading process. The serial server will restart automatically and the system remains intact.
2. If GW21W does not receive any upgrade data within 30 seconds, the serial server will restart
automatically and the system remains intact.
3. After the upgrading process finishes, the serial server will program the flash memory and buzzer
beeps 6 times then restarts. Normally, it takes around 10 seconds to complete the programming
process. If an error occurs during the programming process,GW21W will clear the corresponding
memory and the system remains intact of what it was.
B.3 Error Messages
Firmware upgrade may not be successful if errors occur during the process.
Error Cause Message Comments
Illegal Hex file format Hex File Text Error
Hex File Check-Sum Error
Hex File Format Error
Hex File End of Record Error
GW21W handshaking problem GW21W ACK Start Address Error
GW21W ACK Length Error