User`s manual

Quick Start Guide Version 1.3
GW51C-MAXI Serial Server
3
4.2.5. Configure by console mode
1. Set MODE switch SW1 to ‘OFF’ and SW2 to ‘ON’, then Power off GW51C-MAXI Serial Server
2.
Use a PC to connect to GW51C-MAXI Serial Server’s console with RS-232 cross over cable
3. Power on Serial Server, then Open terminal program from your computer and Set to 9600, 8, n, 1 without
flow control for console port communication.
4. The following configuration operations are totally the same as those configure by telnet.
5. After finishing console settings, power off GW51C-MAXI Serial Server, put SW1 and SW2 back to previous
setting.
5. Pin Assignments
5.1. 8 pin Mini DIN connector
-Atop provides Mini DIN connector to DB9 connector cable, the pin
assignments is shown in the following table and RS-485 2 or 4 pins assignments of DB9 connector are different
from those of Mini DIN connector.
Pin#
RS-232
Full Duplex
RS-485
2 wire, Half Duplex
RS-422/RS-485 4 wire,
Full Duplex
1 DCD N/A N/A
2 RXD N/A (reserved)
TXD+
3 TXD
DATA+
RXD+
4 DTR N/A N/A
5 SG (Signal Ground) SG (Signal Ground) SG (Signal Ground)
6 DSR N/A N/A
7 RTS
DATA- RXD-
8 CTS N/A (reserved)
TXD-
9 N/A N/A N/A
6. Customer Services and Supports
Contact your local dealers or ATOP Technical Support Center at the following numbers.
+886-3-550-8137 (ATOP Taiwan)
+86-21-6495-6232 (ATOP China)
Report the errors via Atop’s Web site or E-mail account
www.atop.com.tw, service@atop.com.tw
www.atop.com.cn, service@atop.com.cn