® ABLELink GW51C-MAXI Serial Server Quick Start Guide Version 1.3 Updated on February, 2008. TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.
Quick Start Guide Version 1.3 GW51C-MAXI Serial Server This document is intended to provide customers with brief descriptions on the product and to assist customers to get started. For detail information and operations of the product, please refer to the user’s manual in the product CD. 1.
Quick Start Guide Version 1.3 GW51C-MAXI Serial Server LED on Jumper JP1 pin1 and pin2 are short to disable AP firmware in the flash memory. LED blinking (rate: 0.5Sec) AP firmware is running 3. Installation Procedures MODE Switch This sets or initializes operating mode for the Serial Server. The factory default setting is that Switch 1 (SW1) and Switch 2 (SW2) are set to OFF. One can use the Mode switch to change the operating mode from the factory default settings to ones desired mode.
Quick Start Guide Version 1.3 GW51C-MAXI Serial Server 4.2.5. Configure by console mode 1. Set MODE switch SW1 to ‘OFF’ and SW2 to ‘ON’, then Power off GW51C-MAXI Serial Server 2. Use a PC to connect to GW51C-MAXI Serial Server’s console with RS-232 cross over cable 3. Power on Serial Server, then Open terminal program from your computer and Set to 9600, 8, n, 1 without flow control for console port communication. 4. The following configuration operations are totally the same as those configure by telnet.