Specifications

33
Variety of Applications
Cyclonic Spray Chambers
Ryton
®
Scott Spray Chambers
Ryton
®
Scott Spray Chambers
PFA Teflon
®
Scott Spray Chamber
UltraClean, low volume 47 mm Scott Spray Chamber. For use with
concentric nebulizers. Requires a PFA injector assembly and the PFA
End Cap (N8122357).
Description Part No.
PFA Teflon
®
Scott Spray Chamber N8122356
Water-Cooled Glass Scott Spray Chamber
Water-Cooled Glass Scott Spray Chamber included in Heavy Organics
Sample Introduction System (N8122132). Recommended for use with
heavy organic solvents.
Does not include end cap.
ICP-MS Model Part No.
ELAN DRCe/9000/6X00/5000 WE013829
The Cyclonic Spray Chamber relies on momentum to efficiently and
quickly remove the larger droplets from the sample mist decreasing any
opportunity for occlusion or agglomeration of the smaller droplets. The
result is higher efficiency, better precision and faster washouts than other
spray chamber designs.
Decreased sample introduction system installation and optimization
time due to the preset nature of the spray chamber/nebulizer combination
More samples per hour due to minimal dead volume and efficient draining
Unique design characteristics:
The nebulizer port is oversized so that sample solution cannot build up
around the nebulizer as it will in other cyclonic designs
The nebulizer port angle is tightly controlled so that the nebulizer
mist impacts on the same chamber wall area in each and
every spray chamber
Each spray chamber incorporates a precisely machined ridge along
the inside top of the spray chamber. This eliminates the periodic “spiking”
that adversely affects precision and fosters faster washout times
Glass Cyclonic
Spray Chamber Kit
For ELAN DRCe/9000/6X00/5000. Kit
contains one Glass Cyclonic Spray
Chamber, mounting hardware and
instructions. Requires, but does
not include, a concentric nebulizer.
Description Part No.
Glass Cyclonic Spray Chamber Kit N8120150
Glass Cyclonic Spray Chamber only N8122188
O-Ring Free Glass Cyclonic Spray Chamber N0775350
Water-Cooled O-Ring Free
Glass Cyclonic Spray Chamber
O-Ring Free Glass Cyclonic Spray Chamber only. Ball joint type.
ICP-MS Model Part No.
ELAN DRC/DRC
plus
/DRC II N0775354
Twister Cyclonic Spray Chamber
Part No.
N0773196
IsoMist
Programmable
Temperature
Spray Chamber
The IsoMist Programmable
Temperature Spray Chamber lets you select any temperature between
-10 °C and +60 °C in 1 °C increments to provide the optimum
conditions for any application. The rapid response of the Peltier
device allows a spray chamber temperature of -5 °C to be reached
within 15 minutes.
For ELAN 9000/6X00/5000/DRC-e. Complete HF-resistant Ryton
®
Scott Spray
Chamber. Includes (1) large O-Ring (WE013060), (1) Retaining Ring (WE014081)
and (1) Right-Angled Drain Connector (WE013119).
Description Part No.
Ryton
®
Scott Spray Chamber N8120124
Ryton
®
Scott Spray Chamber Large O-Ring WE013060
Ryton
®
Scott Spray Chamber Retaining Ring WE014081
ORDER TODAY
Order online at www.perkinelmer.com/supplies
PC
3
Spray Chamber
The PC
3
cools the outer walls of the
Cyclonic Spray Chamber to a
constant temperature. This reduces
polyatomic ion interferences, such
as oxides, for ICP-MS analysis.
ICP-MS Model Part No.
Cassette Torch Mount N8122410
Twist Type Torch Mount N8122389
Part No.
N0777364