Specifications

24
PerkinElmer Spray Chambers for all of Your
Superior quality Spray Chambers
designed to provide
maximum
sensitivity
and efficiency
Save Time and Expense
Decreased sample introduction system installation and
optimization time due to the preset nature of the spray
chamber/nebulizer combination
More samples per hour due to minimal dead volume and
efficient draining
Unique Design Characteristics
The nebulizer port is oversized so that sample solution cannot
build up around the nebulizer as it will in other cyclonic designs.
This translates to less carryover, faster washout times and greater
productivity from your Optima
The nebulizer port angle is tightly controlled so that the nebulizer
mist impacts on the same chamber wall area in each and every
spray chamber. The angle of incidence is critical in determining the
efficiency of large droplet removal
A trace metal free plastic nebulizer adapter is employed to fix the
depth of nebulizer insertion at the optimal position. Because of this,
there is no need for an operator to move the nebulizer in and out of
the port in an effort to locate the “sweet spot”
Each spray chamber incorporates a precisely-machined ridge along
the inside top of the spray chamber. Both the angle and depth of the
ridge are critical to performance. The result is efficient draining of
sample waste and the elimination of large droplets being swept into
the plasma. This eliminates the periodic “spiking” that adversely
affects precision and fosters faster washout times
The spray chamber is an integral part of the sample introduction
system responsible for filtering the sample mist to permit the
appropriate droplet size distribution to reach the plasma.
The cyclonic spray chamber relies on momentum to efficiently
and quickly remove the larger droplets from the sample mist
decreasing any opportunity for occlusion or agglomeration
of the smaller droplets. The result is higher efficiency, better
precision and faster washouts than other spray chamber designs.
Cyclonic Spray Chambers
Standard and 0-Ring Free glass cyclonic spray chambers can be used with either
GemCone or concentric glass nebulizers. HF resistant cyclonic spray chambers
should be used with GemCone, SeaSpray or MicroMist nebulizers.
ICP Model Type Part No.
Optima 2X00/4X00/5X00/7X00 Standard N0776052
Optima 2X00/4X00/5X00/7X00 O-Ring Free N0775351
Optima 2X00/4X00/5X00/7X00 HF Resistant N0777496
Optima 3X00 DV/XL/3000 SCX Standard N8122188
Optima 3X00 DV/XL/3000 SCX O-Ring Free N0775350
See
page 2
for ordering information and a complete listing of PerkinElmer offices
.
New! Glass Cyclonic Spray Chambers
Type Model Part No.
Cinnabar Spray Chamber with Helix Optima 2/4/5/7X00 DV N0777494
Twinnabar Spray Chamber with Helix Optima 2/4/5/7X00 DV N0777495
Tracey TFE Spray Chamber with Helix Optima 2/4/5/7X00 DV N0777496
Tracey TFE Spray Chamber with Helix Optima 4300/5300/7300 V N0777497
Please see website for more details.